BLUERIDGE / AIR-SOURCE HEAT PUMP

BHP17L30P-**A

BHP17 SERIES · BHP17 Series · BHP17L SERIES · BHP17L Series · source records, page 7

139 published source records · source checked Sep 21, 2026

SEER2 range15.4–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,000BTU/h

Each efficiency range summarizes published EPA records for BHP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 139 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–16.2139 / 139
EER2 · BTU/Wh12.2–13.5139 / 139
HSPF2 · BTU/Wh7.8–8.6139 / 139
Cooling capacity · BTU/h28,200–30,000139 / 139
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000139 / 139
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600139 / 139
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400139 / 139
COP at 5°F / −15°C1.98–2.34139 / 139
Equipment / loop typeHP - Split System139 / 139
Refrigerant / source-reported GWPR-410A (GWP:2088)139 / 139
Compressor stagingSingle stage139 / 139
Connected capabilityNo139 / 139

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC736HCT-0*+TDR+ furnace: BG961UH090CE16AHRI reference: 21471339915.608.30145002.22EPA 3487219
BC736HCT-0*+TDR+ furnace: BG961UH110CE20AHRI reference: 21471340015.608.50148002.26EPA 3487221
BC736CBT-0*+TDR+ furnace: BG961UH045BE12AHRI reference: 21471343215.608.10146002.26EPA 3487302
BC736CBT-0*+TDR+ furnace: BG961UH070BE12AHRI reference: 21471343315.608.10143002.26EPA 3487303
BC736HCT-0*+TDR+ furnace: BG801UH110CE20AHRI reference: 21471339415.608.30146002.22EPA 3491722
BE5C36MA4XAHRI reference: 21117439215.408.10136002.14EPA 2454780
BE5V30MA4XAHRI reference: 21032536115.408.10139002.16EPA 2455694
BC1P30B+TDR+TXV+ furnace: BG961UH045BE12AHRI reference: 21044125515.407.80143002.18EPA 2456501
BC4X30B+TDR+ furnace: BG961UH045BE12AHRI reference: 21044128515.407.80143002.18EPA 2457323
BC1P30A+TDR+TXV+ furnace: BG961UH070BE12AHRI reference: 21032538015.407.80143002.18EPA 2457400
BC1P30B+TDR+TXV+ furnace: BG961UH070BE12AHRI reference: 21044125615.407.80143002.18EPA 2457478
BC4X30B+TDR+ furnace: BG961UH070BE12AHRI reference: 21044128615.407.80143002.18EPA 2459442
BC1P30A+TDR+TXV+ furnace: BG961UH045BE12AHRI reference: 21032537815.407.80143002.18EPA 2461636
BD4X-42B+TDR+ furnace: BG96G1DF045BE12AHRI reference: 21326551215.408.60154002.30EPA 2840040
BC742DBT-0*+TDR+ furnace: BG96G1DF045BE12AHRI reference: 21471340515.408.60154002.30EPA 3487087
BC730CBT-0*+TDR+ furnace: BG961UH045BE12AHRI reference: 21471341715.407.80143002.18EPA 3487116
BC730CBT-0*+TDR+ furnace: BG961UH070BE12AHRI reference: 21471341815.407.80143002.18EPA 3487119
BAH7V30PT-0*AHRI reference: 21486612515.408.10139002.16EPA 3553918
BAH7P36PT-0*AHRI reference: 21486614415.408.10136002.14EPA 3553924

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →