BLUERIDGE / AIR-SOURCE HEAT PUMP

BHP17L30P-**A

BHP17 SERIES · BHP17 Series · BHP17L SERIES · BHP17L Series · source records, page 2

139 published source records · source checked Sep 21, 2026

SEER2 range15.4–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,000BTU/h

Each efficiency range summarizes published EPA records for BHP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 139 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–16.2139 / 139
EER2 · BTU/Wh12.2–13.5139 / 139
HSPF2 · BTU/Wh7.8–8.6139 / 139
Cooling capacity · BTU/h28,200–30,000139 / 139
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000139 / 139
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600139 / 139
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400139 / 139
COP at 5°F / −15°C1.98–2.34139 / 139
Equipment / loop typeHP - Split System139 / 139
Refrigerant / source-reported GWPR-410A (GWP:2088)139 / 139
Compressor stagingSingle stage139 / 139
Connected capabilityNo139 / 139

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC1P36A+TDR+TXV+ furnace: BG802UH070AE12AHRI reference: 21032539116.008.10143002.26EPA 2455607
BC1P30A+TDR+TXV+ furnace: BG801UH090BE16AHRI reference: 21032537116.008.00142002.22EPA 2455755
BC4X30B+TDR+ furnace: BG801UH090BE16AHRI reference: 21044128216.008.00142002.22EPA 2456468
BC4X36B+TDR+ furnace: BG921UH070BE12AHRI reference: 21044129916.008.10144002.28EPA 2456481
BC4X36B+TDR+ furnace: BG802UH090BV16AHRI reference: 21044130216.008.10144002.28EPA 2456495
BC4X36B+TDR+ furnace: BG801UH070BE12AHRI reference: 21044129616.008.10143002.26EPA 2456514
BC4X36A+TDR+ furnace: BG801UH045AE12AHRI reference: 21044128916.008.10144002.28EPA 2456516
BC1P36B+TDR+TXV+ furnace: BG921UH070BE12AHRI reference: 21044126416.008.10144002.28EPA 2456533
BC4X36A+TDR+ furnace: BG802UH070AE12AHRI reference: 21044128816.008.10143002.26EPA 2456546
BC1P30B+TDR+TXV+ furnace: BG801UH090BE16AHRI reference: 21044125216.008.00142002.22EPA 2457282
BC1P36B+TDR+TXV+ furnace: BG801UH070BE12AHRI reference: 21044126116.008.10143002.26EPA 2457291
BC1P36B+TDR+TXV+ furnace: BG802UH090BV16AHRI reference: 21044126716.008.10144002.28EPA 2457316
BC4X30B+TDR+ furnace: BG802UH090BE16AHRI reference: 21044127916.008.00142002.22EPA 2457349
BC1P30B+TDR+TXV+ furnace: BG802UH090BE16AHRI reference: 21044124916.008.00142002.22EPA 2457503
BC1P36A+TDR+TXV+ furnace: BG801UH070AE12AHRI reference: 21032539516.008.10144002.28EPA 2458317
BC1P30A+TDR+TXV+ furnace: BG802UH090BE16AHRI reference: 21032537216.008.00142002.22EPA 2458693
BC4X36A+TDR+ furnace: BG801UH070AE12AHRI reference: 21044129016.008.10144002.28EPA 2458874
BC1P36A+TDR+TXV+ furnace: BG801UH045AE12AHRI reference: 21032539316.008.10144002.28EPA 2461133
BC1P36A+TDR+TXV+ furnace: BG802UH090BV16AHRI reference: 21032541416.008.10144002.28EPA 2461649
BC730HBT-0*+TDR+ furnace: BG921UH070BE12AHRI reference: 21471338916.007.80136002.06EPA 3486945

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →