BLUERIDGE / AIR-SOURCE HEAT PUMP

BHP17L18P-**A

BHP17 SERIES · BHP17 Series · BHP17L SERIES · BHP17L Series · source records, page 2

142 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.4BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for BHP17L18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 142 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8142 / 142
EER2 · BTU/Wh12.2–14142 / 142
HSPF2 · BTU/Wh7.8–8.4142 / 142
Cooling capacity · BTU/h18,000142 / 142
Heating capacity at 47°F / 8.3°C · BTU/h17,000–18,000142 / 142
Heating capacity at 17°F / −8.3°C · BTU/h10,400–11,800142 / 142
Heating capacity at 5°F / −15°C · BTU/h7,600–9,300142 / 142
COP at 5°F / −15°C1.9–2.14142 / 142
Equipment / loop typeHP - Split System142 / 142
Refrigerant / source-reported GWPR-410A (GWP:2088)142 / 142
Compressor stagingSingle stage142 / 142
Connected capabilityNo142 / 142

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC730CAT-0*+TDR+ furnace: BG802UH070AE12AHRI reference: 21471330816.808.0076001.98EPA 3487193
BC730HBT-0*+TDR+ furnace: BG921UH070BE12AHRI reference: 21471328416.808.0076002.00EPA 3491606
BC1P30B+TDR+TXV+ furnace: BG921UH070BE12AHRI reference: 21044114616.607.8077002.02EPA 2456464
BC1P30A+TDR+TXV+ furnace: BG802UH070AV12AHRI reference: 21032560416.608.0080001.98EPA 2457848
BC4X30A+TDR+ furnace: BG802UH070AV12AHRI reference: 21044117716.608.0080001.98EPA 2458860
BC4X30B+TDR+ furnace: BG921UH070BE12AHRI reference: 21044118516.607.8077002.02EPA 2459331
BC1P30A+TDR+TXV+ furnace: BG921UH070BE12AHRI reference: 21032561516.607.8077002.02EPA 2462131
BC730CBT-0*+TDR+ furnace: BG921UH070BE12AHRI reference: 21471331816.607.8077002.02EPA 3486899
BC730CAT-0*+TDR+ furnace: BG802UH070AV12AHRI reference: 21471331116.608.0080001.98EPA 3487049
BC1P24A+TDR+TXV+ furnace: BG802UH070AE12AHRI reference: 21032557116.408.1082002.12EPA 2455442
BC1P30A+TDR+TXV+ furnace: BG961UH045BE12AHRI reference: 21032560816.407.8077001.98EPA 2455544
BC1P24A+TDR+TXV+ furnace: BG801UH070AE12AHRI reference: 21032556716.408.0082002.10EPA 2455682
BC1P24A+TDR+TXV+ furnace: BG801UH070BE12AHRI reference: 21032557516.408.0082002.10EPA 2455752
BC4X30B+TDR+ furnace: BG802UH090BV16AHRI reference: 21044118816.408.0080001.96EPA 2456069
BC1P30B+TDR+TXV+ furnace: BG961UH070BE12AHRI reference: 21044114816.407.8077001.98EPA 2456429
BC4X24A+TDR+ furnace: BG801UH070AE12AHRI reference: 21044116216.408.0082002.10EPA 2456474
BC4X24B+TDR+ furnace: BG801UH070BE12AHRI reference: 21044116716.408.0082002.10EPA 2456478
BC1P30B+TDR+TXV+ furnace: BG802UH090BV16AHRI reference: 21044114916.408.0080001.96EPA 2456484
BC4X24B+TDR+ furnace: BG802UH090BE12AHRI reference: 21044116416.408.1081002.12EPA 2456497
BC4X24A+TDR+ furnace: BG802UH070AE12AHRI reference: 21044116016.408.1082002.12EPA 2457114

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →