BLUERIDGE / AIR-SOURCE HEAT PUMP

BH719M36P-**A

BH719M SERIES · BH719M Series · source records, page 6

144 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity21,600–35,800BTU/h

Each efficiency range summarizes published EPA records for BH719M36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 144 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–20144 / 144
EER2 · BTU/Wh11–13.2144 / 144
HSPF2 · BTU/Wh7.8–8.5144 / 144
Cooling capacity · BTU/h21,600–35,800144 / 144
Heating capacity at 47°F / 8.3°C · BTU/h22,800–36,000144 / 144
Heating capacity at 17°F / −8.3°C · BTU/h14,500–21,600144 / 144
Heating capacity at 5°F / −15°C · BTU/h13,600–17,000144 / 144
COP at 5°F / −15°C1.48–2.12144 / 144
Equipment / loop typeHP - Split System144 / 144
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)144 / 144
Compressor stagingContinuously variable144 / 144
Connected capabilityNo144 / 144

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC736HCT-**+TDR+ furnace: B97UR1102V5CAHRI reference: 21750523917.008.10164002.08EPA 4469017
BC736HCT-**+TDR+ furnace: B80UR1002V5CXAHRI reference: 21750524317.008.10164002.08EPA 4469033
BC736HCT-**+TDR+ furnace: B97UR1002V5CXAHRI reference: 21750525117.008.00165002.06EPA 4469044
BC730HBT-**+TDR+ furnace: B96UR701E4BAHRI reference: 21750553617.008.50151001.90EPA 4469096
BC730HBT-**+TDR+ furnace: B97UR702E3BAHRI reference: 21750555217.008.50152001.88EPA 4469105
BC730HBT-**+TDR+ furnace: B80UR701E3BAHRI reference: 21750552217.008.50151001.90EPA 4469422
BC736HCT-**+TDR+ furnace: B97UR902V3CAHRI reference: 21754758717.008.10165002.06EPA 4469828
BC736HCT-**+TDR+ furnace: B80UR1102V5CAHRI reference: 21754758617.008.10167002.06EPA 4469863
BC736[C,U]CT-**+TDR+ furnace: B96UR901E4CAHRI reference: 21845871117.008.20147001.94EPA 4617481
BC736[C,U]CT-**+TDR+ furnace: B92UR901E4CAHRI reference: 21845867217.008.20147001.94EPA 4617502
BAH7P24PT-**AHRI reference: 21750539916.508.20156001.74EPA 4468983
BC736HCT-**+TDR+ furnace: B92UR901E4CAHRI reference: 21750523516.508.20162002.08EPA 4469002
BC736HCT-**+TDR+ furnace: B92UR1101E4CAHRI reference: 21750523616.508.20162002.08EPA 4469005
BC736HCT-**+TDR+ furnace: B96UR901E4CAHRI reference: 21750523716.508.20163002.08EPA 4469025
BC736HCT-**+TDR+ furnace: B97UR902E4CAHRI reference: 21750525416.508.20163002.08EPA 4469045
BC730HBT-**+TDR+ furnace: B95UR401E3BXAHRI reference: 21750551616.508.20153001.88EPA 4469086
BC730HBT-**+TDR+ furnace: B95UR601E3BXAHRI reference: 21750551816.508.20153001.88EPA 4469088
BC730HBT-**+TDR+ furnace: B96UR451E3BAHRI reference: 21750553316.508.20153001.88EPA 4469095
BC730[C,U]AT-**+TDRAHRI reference: 21750554516.508.00144001.82EPA 4469102
BC730HBT-**+TDR+ furnace: B97UR452E3BAHRI reference: 21750555416.508.50152001.88EPA 4469109

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →