BLUERIDGE / AIR-SOURCE HEAT PUMP

BH714S24P-**A

BH714S SERIES · BH714S Series · source records, page 4

86 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,800–24,000BTU/h

Each efficiency range summarizes published EPA records for BH714S24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 86 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1686 / 86
EER2 · BTU/Wh12–13.886 / 86
HSPF2 · BTU/Wh7.8–8.286 / 86
Cooling capacity · BTU/h22,800–24,00086 / 86
Heating capacity at 47°F / 8.3°C · BTU/h20,400–23,00086 / 86
Heating capacity at 17°F / −8.3°C · BTU/h12,900–14,70086 / 86
Heating capacity at 5°F / −15°C · BTU/h10,500–11,60086 / 86
COP at 5°F / −15°C1.96–2.1886 / 86
Equipment / loop typeHP - Split System86 / 86
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)86 / 86
Compressor stagingSingle stage86 / 86
Connected capabilityNo86 / 86

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC724[C,U]BT-**+TDR+ furnace: B97UR602V3BXAHRI reference: 21637144315.207.80108002.02EPA 3813340 →
BC730[C,U]AT-**+TDR+ furnace: B80UR401E3AXAHRI reference: 21637144415.208.00115002.14EPA 3813341 →
BC730[C,U]AT-**+TDR+ furnace: B80UR601E3AXAHRI reference: 21637144515.208.00115002.14EPA 3813342 →
BC730[C,U]AT-**+TDR+ furnace: B80UR702E3AAHRI reference: 21637144615.208.00116002.14EPA 3813343 →
BC730HAT-**+TDR+ furnace: B80UR702E3AAHRI reference: 21637149015.208.00113002.04EPA 3813347 →
BC730HAT-**+TDR+ furnace: B80UR451E3AAHRI reference: 21637149115.207.80109002.02EPA 3813348 →
BC730HAT-**+TDR+ furnace: B80UR701E3AAHRI reference: 21637149215.208.00110002.04EPA 3813349 →
BC730HAT-**+TDR+ furnace: B80UR402V3AXAHRI reference: 21637149315.208.00111002.04EPA 3813350 →
BC730HBT-**+TDR+ furnace: B80UR801E4BXAHRI reference: 21637149415.208.00111002.06EPA 3813351 →
BC730HBT-**+TDR+ furnace: B95UR401E3BXAHRI reference: 21637149515.207.80112002.04EPA 3813352 →
BC730HBT-**+TDR+ furnace: B95UR601E3BXAHRI reference: 21637149615.208.00112002.04EPA 3813353 →
BC730[C,U]BT-**+TDR+ furnace: B92UR701E3BAHRI reference: 21637146015.208.10115002.14EPA 3813753 →
BC730HBT-**+TDR+ furnace: B80UR602V3AXAHRI reference: 21637150715.207.80110002.04EPA 3813754 →
BC730/36DBT-**+TDR+ furnace: B80DR901E4BAHRI reference: 21637151915.208.20113002.10EPA 3813773 →
BC730/36DCT-**+TDR+ furnace: B97DR902E4CAHRI reference: 21637152015.208.20113002.10EPA 3813774 →
BC724HBT-**+TDR+ furnace: B97UR452V3BAHRI reference: 21649887915.208.00106001.98EPA 3847434 →
BC724[C,U]AT-**+TDR+ furnace: B80UR702V3AAHRI reference: 21680170215.207.80109002.02EPA 3993052 →
BC724[C,U]BT-**+TDR+ furnace: B80UR902V4BAHRI reference: 21680170315.207.80108002.00EPA 3993053 →
BC730[C,U]BT-**+TDR+ furnace: B80UR902V4BAHRI reference: 21680170615.207.80114002.14EPA 3993081 →
BC724HAT-**+TDR+ furnace: B80UR702V3AAHRI reference: 21680170915.207.80107001.96EPA 3993082 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →