A7SCP18V60P-**A
A7SCP18V Series · source records, page 7
250 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for A7SCP18V60P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 250 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.3 | 250 / 250 |
| EER2 · BTU/Wh | 9.6–11.7 | 250 / 250 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 250 / 250 |
| Cooling capacity · BTU/h | 42,500–55,500 | 250 / 250 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–56,500 | 250 / 250 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,000–45,000 | 250 / 250 |
| Heating capacity at 5°F / −15°C · BTU/h | 39,000–45,000 | 250 / 250 |
| COP at 5°F / −15°C | 1.75–1.95 | 250 / 250 |
| Equipment / loop type | HP - Split System | 250 / 250 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 250 / 250 |
| Compressor staging | Continuously variable | 250 / 250 |
| Connected capability | No | 250 / 250 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7EH60DX-**+TDR+ furnace: A98USMV135D20S*Cold climate designationAHRI reference: 217189096 | 16.45 | 8.50 | 40500 | 1.85 | EPA 4007216 → |
7EH42BX-**+TDR+ furnace: A80US2V080B16X*Cold climate designationAHRI reference: 217450410 | 16.45 | 9.00 | 39000 | 1.90 | EPA 4046064 → |
7EH48CX-**+TDR+ furnace: A93UH1E110C16A*Cold climate designationAHRI reference: 217450428 | 16.45 | 8.50 | 39500 | 1.80 | EPA 4046075 → |
7EH48BX-**+TDR+ furnace: A80US2V080B16X*Cold climate designationAHRI reference: 217450422 | 16.45 | 9.00 | 40000 | 1.80 | EPA 4046557 → |
7ED48CX-**+TDR+ furnace: A97DSMV090C20S*Cold climate designationAHRI reference: 217450438 | 16.45 | 9.00 | 40000 | 1.85 | EPA 4046565 → |
7EH51CX-**+TDR+ furnace: A98USMV110C20S*Cold climate designationAHRI reference: 217897410 | 16.45 | 8.50 | 41000 | 1.85 | EPA 4512319 → |
7E[C,U]48CX-**+TDR+ furnace: A97US2V080C16X*Cold climate designationAHRI reference: 216769736 | 16.40 | 8.50 | 39500 | 1.80 | EPA 3984001 → |
7EH60DX-**+TDR+ furnace: A97US2V135D20S*Cold climate designationAHRI reference: 216769822 | 16.40 | 8.50 | 40500 | 1.85 | EPA 3984005 → |
7EH42CX-**+TDR+ furnace: A80US2V080C20X*Cold climate designationAHRI reference: 217189053 | 16.40 | 8.50 | 39500 | 1.80 | EPA 4007019 → |
7EH42CX-**+TDR+ furnace: A80US2V100C20X*Cold climate designationAHRI reference: 217189054 | 16.40 | 8.50 | 39500 | 1.80 | EPA 4007020 → |
7EH42CX-**+TDR+ furnace: A98USMV110C20S*Cold climate designationAHRI reference: 217189057 | 16.40 | 8.50 | 39500 | 1.80 | EPA 4007023 → |
7ED48CX-**+TDR+ furnace: A96DF1E110C20S*Cold climate designationAHRI reference: 217450440 | 16.40 | 9.00 | 39500 | 1.90 | EPA 4046566 → |
7EH50/60CX-**+TDR+ furnace: A97US2V110C20S*Cold climate designationAHRI reference: 216769798 | 16.35 | 8.50 | 40500 | 1.85 | EPA 3983607 → |
7EH42CX-**+TDR+ furnace: A97US2V080C20X*Cold climate designationAHRI reference: 216769754 | 16.35 | 8.50 | 39500 | 1.80 | EPA 3983791 → |
7EH42CX-**+TDR+ furnace: A97US2V110C20S*Cold climate designationAHRI reference: 216769756 | 16.35 | 8.50 | 39500 | 1.80 | EPA 3983793 → |
7EH48CX-**+TDR+ furnace: A80US2V110C20*Cold climate designationAHRI reference: 217189064 | 16.35 | 8.50 | 40000 | 1.80 | EPA 4006959 → |
7E[C,U]48BX-**+TDR+ furnace: A80UH1E080B16X*Cold climate designationAHRI reference: 217189020 | 16.35 | 8.50 | 39500 | 1.80 | EPA 4007164 → |
7EH42CX-**+TDR+ furnace: A97US2V110C16S*Cold climate designationAHRI reference: 217450414 | 16.35 | 8.50 | 39500 | 1.80 | EPA 4046185 → |
7EH48CX-**+TDR+ furnace: A80US2V090C20*Cold climate designationAHRI reference: 217450429 | 16.35 | 8.50 | 39500 | 1.80 | EPA 4046647 → |
7EH48CX-**+TDR+ furnace: A80US2V110C20L*Cold climate designationAHRI reference: 217450430 | 16.35 | 8.50 | 40000 | 1.80 | EPA 4046648 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →