A7SCP18V60P-**A
A7SCP18V Series · source records, page 2
250 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for A7SCP18V60P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 250 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.3 | 250 / 250 |
| EER2 · BTU/Wh | 9.6–11.7 | 250 / 250 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 250 / 250 |
| Cooling capacity · BTU/h | 42,500–55,500 | 250 / 250 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–56,500 | 250 / 250 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,000–45,000 | 250 / 250 |
| Heating capacity at 5°F / −15°C · BTU/h | 39,000–45,000 | 250 / 250 |
| COP at 5°F / −15°C | 1.75–1.95 | 250 / 250 |
| Equipment / loop type | HP - Split System | 250 / 250 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 250 / 250 |
| Compressor staging | Continuously variable | 250 / 250 |
| Connected capability | No | 250 / 250 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7E[C,U]49CX-**+TDR+ furnace: A97US2V110C16S*Cold climate designationAHRI reference: 217450402 | 17.35 | 9.00 | 39500 | 1.85 | EPA 4046315 → |
7E[C,U]49CX-**+TDR+ furnace: A93UH1E090C16A*Cold climate designationAHRI reference: 217450403 | 17.30 | 9.00 | 39500 | 1.85 | EPA 4046316 → |
7E[C,U]49CX-**+TDR+ furnace: A97US2V080C20X*Cold climate designationAHRI reference: 216769746 | 17.25 | 9.00 | 39500 | 1.85 | EPA 3983714 → |
7ED48CX-**+TDR+ furnace: A96DF1E090C16S*Cold climate designationAHRI reference: 217189072 | 17.25 | 9.00 | 39000 | 1.90 | EPA 4007185 → |
7ED48CX-**+TDR+ furnace: A93DF1E090C16A*Cold climate designationAHRI reference: 217450436 | 17.25 | 9.00 | 39000 | 1.90 | EPA 4046563 → |
7E[C,U]49CX-**+TDR+ furnace: A97US2V110C20S*Cold climate designationAHRI reference: 216769748 | 17.20 | 9.00 | 39500 | 1.85 | EPA 3983715 → |
7E[C,U]49CX-**+TDR+ furnace: A80UH1E090C20*Cold climate designationAHRI reference: 217189041 | 17.20 | 9.00 | 39500 | 1.85 | EPA 4007094 → |
7E[C,U]49CX-**+TDR+ furnace: A80UH1E110C20*Cold climate designationAHRI reference: 217189042 | 17.20 | 9.00 | 39500 | 1.85 | EPA 4007095 → |
7E[C,U]49CX-**+TDR+ furnace: A97UH2E090C16S*Cold climate designationAHRI reference: 217450400 | 17.20 | 9.00 | 39000 | 1.85 | EPA 4046313 → |
7ED48CX-**+TDR+ furnace: A80DF1E110C20*Cold climate designationAHRI reference: 217189073 | 17.15 | 9.00 | 39000 | 1.90 | EPA 4007186 → |
7E[C,U]60CX-**+TDR+ furnace: A80UH1E090C20*Cold climate designationAHRI reference: 217189080 | 17.15 | 8.50 | 40500 | 1.90 | EPA 4007249 → |
7E[C,U]60CX-**+TDR+ furnace: A80UH1E110C20*Cold climate designationAHRI reference: 217189081 | 17.15 | 8.50 | 40500 | 1.90 | EPA 4007250 → |
7EH48CX-**+TDR+ furnace: A97US2V090C16S*Cold climate designationAHRI reference: 217450425 | 17.15 | 9.00 | 39500 | 1.80 | EPA 4046560 → |
7ED48CX-**+TDR+ furnace: A80DS2V110C20*Cold climate designationAHRI reference: 217450437 | 17.15 | 9.00 | 39500 | 1.90 | EPA 4046564 → |
7E[C,U]49CX-**+TDR+ furnace: A97US2V090C20S*Cold climate designationAHRI reference: 216769750 | 17.10 | 9.00 | 39500 | 1.85 | EPA 3983787 → |
7E[C,U]49CX-**+TDR+ furnace: A98USMV090C20S*Cold climate designationAHRI reference: 217189044 | 17.10 | 9.00 | 39500 | 1.85 | EPA 4006940 → |
7E[C,U]48CX-**+TDR+ furnace: A80US2V110C20*Cold climate designationAHRI reference: 217189025 | 17.10 | 8.50 | 39500 | 1.80 | EPA 4007169 → |
7ED48CX-**+TDR+ furnace: A97DSMV090C16S*Cold climate designationAHRI reference: 217189071 | 17.10 | 9.00 | 39500 | 1.90 | EPA 4007184 → |
7ED48CX-**+TDR+ furnace: A97DF2E090C16S*Cold climate designationAHRI reference: 217450435 | 17.10 | 9.00 | 39000 | 1.90 | EPA 4046079 → |
7E[C,U]60CX-**+TDR+ furnace: A80US2V090C20*Cold climate designationAHRI reference: 217450445 | 17.10 | 8.50 | 40000 | 1.90 | EPA 4046192 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.