A7HP19V60P-**A
A7HP19V SERIES · A7HP19V Series · source records, page 2
64 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for A7HP19V60P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 64 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16.5–18.5 | 64 / 64 |
| EER2 · BTU/Wh | 11–11.7 | 64 / 64 |
| HSPF2 · BTU/Wh | 7.8–9 | 64 / 64 |
| Cooling capacity · BTU/h | 46,500–48,000 | 64 / 64 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–48,000 | 64 / 64 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 27,600–31,200 | 64 / 64 |
| Heating capacity at 5°F / −15°C · BTU/h | 21,800–29,600 | 64 / 64 |
| COP at 5°F / −15°C | 1.8–2.06 | 64 / 64 |
| Equipment / loop type | HP - Split System | 64 / 64 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 64 / 64 |
| Compressor staging | Continuously variable | 64 / 64 |
| Connected capability | No | 64 / 64 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7E[C,U]50/60CX-**+TDR+ furnace: A97US2V090C16S*AHRI reference: 217202920 | 18.00 | 8.20 | 23800 | 1.84 | EPA 4012204 → |
7E[C,U]50/60CX-**+TDR+ furnace: A97US2V090C20S*AHRI reference: 217202921 | 18.00 | 8.20 | 23800 | 1.86 | EPA 4012205 → |
7E[C,U]48CX-**+TDR+ furnace: A80UH2E110C16*AHRI reference: 217202926 | 18.00 | 7.80 | 22000 | 1.82 | EPA 4012210 → |
7E[C,U]48CX-**+TDR+ furnace: A80UH1E110C20*AHRI reference: 217202929 | 18.00 | 7.80 | 22200 | 1.82 | EPA 4012213 → |
7E[C,U]48CX-**+TDR+ furnace: A93UH1E090C16A*AHRI reference: 217202930 | 18.00 | 7.80 | 22000 | 1.80 | EPA 4012214 → |
7E[C,U]48CX-**+TDR+ furnace: A93UH1E110C16A*AHRI reference: 217202931 | 18.00 | 7.80 | 22000 | 1.82 | EPA 4012215 → |
7E[C,U]48CX-**+TDR+ furnace: A96UH1E090C16S*AHRI reference: 217202933 | 18.00 | 7.80 | 22000 | 1.82 | EPA 4012251 → |
7EH48CX-**+TDR+ furnace: A80UH2E110C16*AHRI reference: 217202945 | 18.00 | 7.80 | 23400 | 1.80 | EPA 4012254 → |
7E[C,U]48CX-**+TDR+ furnace: A97UH2E090C16S*AHRI reference: 217202948 | 18.00 | 7.80 | 22000 | 1.82 | EPA 4012255 → |
7E[C,U]48BX-**+TDR+ furnace: A80UH2E090B16*AHRI reference: 217202962 | 18.00 | 7.80 | 22200 | 1.80 | EPA 4012259 → |
7E[C,U]48BX-**+TDR+ furnace: A80UH1E090B16*AHRI reference: 217202968 | 18.00 | 7.80 | 22000 | 1.82 | EPA 4012260 → |
7E[C,U]50/60CX-**+TDR+ furnace: A80UH1E090B16*AHRI reference: 217455929 | 18.00 | 8.20 | 23400 | 1.88 | EPA 4048076 → |
7E[C,U]48CX-**+TDR+ furnace: A80UH1E090B16*AHRI reference: 217455930 | 18.00 | 7.80 | 22000 | 1.82 | EPA 4048077 → |
7ED50/60CX-**+TDR+ furnace: A80DF1E110C20*AHRI reference: 217455966 | 18.00 | 8.00 | 28800 | 1.96 | EPA 4048088 → |
7ED50/60CX-**+TDR+ furnace: A93DF1E090C16A*AHRI reference: 217455967 | 18.00 | 8.00 | 29400 | 1.92 | EPA 4048089 → |
7E[C,U]50/60CX-**+TDR+ furnace: A97US2V110C20S*AHRI reference: 217727990 | 18.00 | 8.20 | 23800 | 1.86 | EPA 4512879 → |
7EH48CX-**+TDR+ furnace: A97UH1E080C16*AHRI reference: 218788133 | 18.00 | 7.80 | 23800 | 1.80 | EPA 4706553 → |
7E[C,U]50/60CX-**+TDR+ furnace: A97UH1E080C16*AHRI reference: 218788132 | 18.00 | 8.20 | 24400 | 1.96 | EPA 4706554 → |
7E[C,U]48CX-**+TDR+ furnace: A97UH1E080C16*AHRI reference: 218788130 | 18.00 | 7.80 | 22800 | 1.86 | EPA 4706556 → |
7E[C,U]50/60CX-**+TDR+ furnace: A80UH1E100C20X*AHRI reference: 217202900 | 17.50 | 8.20 | 23800 | 1.84 | EPA 4012185 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →