Armstrong Air / AIR-SOURCE HEAT PUMP

A7HP19V36P-**A

A7HP19V SERIES · A7HP19V Series · source records, page 9

202 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity21,600–35,600BTU/h

Each efficiency range summarizes published EPA records for A7HP19V36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 202 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–20202 / 202
EER2 · BTU/Wh11–13.2202 / 202
HSPF2 · BTU/Wh7.8–8.5202 / 202
Cooling capacity · BTU/h21,600–35,600202 / 202
Heating capacity at 47°F / 8.3°C · BTU/h22,800–36,000202 / 202
Heating capacity at 17°F / −8.3°C · BTU/h13,900–23,000202 / 202
Heating capacity at 5°F / −15°C · BTU/h12,100–17,700202 / 202
COP at 5°F / −15°C1.48–2.2202 / 202
Equipment / loop typeHP - Split System202 / 202
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)202 / 202
Compressor stagingContinuously variable202 / 202
Connected capabilityNo202 / 202

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH30BX-**+TDR+ furnace: A97UH1E030B12*AHRI reference: 21878811317.008.10149001.80EPA 4706573
7EH36CX-**+TDR+ furnace: A97UH1E060B12*AHRI reference: 21878810917.008.10170002.04EPA 4706577
7EH30BX-**+TDR+ furnace: EFV08BCA*AHRI reference: 21754772716.908.20154001.86EPA 4469918
7E[C,U]36BX-**+TDR+ furnace: A80UH1E080B16X*AHRI reference: 21720275016.508.20148001.92EPA 4012085
7EH36CX-**+TDR+ furnace: A80UH2E110C16*AHRI reference: 21720283916.508.20161002.10EPA 4012110
7EH36CX-**+TDR+ furnace: A93UH1E090C16A*AHRI reference: 21720284816.508.20162002.08EPA 4012113
7EH36CX-**+TDR+ furnace: A93UH1E110C16A*AHRI reference: 21720285016.508.20162002.08EPA 4012114
7EH36CX-**+TDR+ furnace: A96UH1E090C16S*AHRI reference: 21720285216.508.20163002.08EPA 4012115
7EH36CX-**+TDR+ furnace: A80US2V110C20*AHRI reference: 21720286116.508.00164002.08EPA 4012119
7EH36CX-**+TDR+ furnace: A80US2V110C20L*AHRI reference: 21720286416.508.00164002.08EPA 4012120
7EH36CX-**+TDR+ furnace: A98USMV090C20S*AHRI reference: 21720287916.508.00165002.06EPA 4012162
7EH36CX-**+TDR+ furnace: A97UH2E090C16S*AHRI reference: 21720288016.508.20163002.08EPA 4012163
7AH1AC24PX-**AHRI reference: 21720302216.508.20156001.74EPA 4012167
7EH36CX-**+TDR+ furnace: A97US2V090C20S*AHRI reference: 21720288516.508.00165002.06EPA 4012183
7ED30/36CX-**+TDR+ furnace: A80DS2V110C20*AHRI reference: 21745592616.508.00165002.12EPA 4048073
7ED30/36CX-**+TDR+ furnace: A97DSMV090C20S*AHRI reference: 21745592716.508.00167002.08EPA 4048074
7E[C,U]30BX-**+TDRAHRI reference: 21745597716.508.00144001.82EPA 4048098
7EH30BX-**+TDR+ furnace: A96UH1E045B12S*AHRI reference: 21745603516.508.20153001.88EPA 4048158
7E[C,U]30AX-**+TDRAHRI reference: 21745604716.508.00144001.82EPA 4048192
7EH30BX-**+TDR+ furnace: A97UH2E045B12S*AHRI reference: 21745605516.508.50152001.88EPA 4048212

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →