Armstrong Air / AIR-SOURCE HEAT PUMP

A7HP19V36P-**A

A7HP19V SERIES · A7HP19V Series · source records, page 7

202 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity21,600–35,600BTU/h

Each efficiency range summarizes published EPA records for A7HP19V36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 202 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–20202 / 202
EER2 · BTU/Wh11–13.2202 / 202
HSPF2 · BTU/Wh7.8–8.5202 / 202
Cooling capacity · BTU/h21,600–35,600202 / 202
Heating capacity at 47°F / 8.3°C · BTU/h22,800–36,000202 / 202
Heating capacity at 17°F / −8.3°C · BTU/h13,900–23,000202 / 202
Heating capacity at 5°F / −15°C · BTU/h12,100–17,700202 / 202
COP at 5°F / −15°C1.48–2.2202 / 202
Equipment / loop typeHP - Split System202 / 202
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)202 / 202
Compressor stagingContinuously variable202 / 202
Connected capabilityNo202 / 202

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7E[C,U]36BX-**+TDR+ furnace: A80UH1E090B16*AHRI reference: 21720275417.508.20147001.94EPA 4011925
7EH36CX-**+TDR+ furnace: A93UH1E090C12A*AHRI reference: 21720284517.508.20163002.06EPA 4012112
7EH36CX-**+TDR+ furnace: A80US2V080C20X*AHRI reference: 21720285517.508.00164002.08EPA 4012116
7EH36CX-**+TDR+ furnace: A97US2V080C16X*AHRI reference: 21720286517.508.10165002.06EPA 4012121
7EH36CX-**+TDR+ furnace: A98USMV090C12S*AHRI reference: 21720286617.508.00165002.06EPA 4012122
7EH36CX-**+TDR+ furnace: A97US2V090C12S*AHRI reference: 21720288217.508.00165002.06EPA 4012164
7EH30BX-**+TDR+ furnace: A80UH2E090B12*AHRI reference: 21745602017.508.20149001.88EPA 4048144
7EH30BX-**+TDR+ furnace: A93UH1E030B12A*AHRI reference: 21745602917.508.20150001.88EPA 4048152
7EH30BX-**+TDR+ furnace: A93UH1E070B12A*AHRI reference: 21745603317.508.50151001.90EPA 4048156
7EH30BX-**+TDR+ furnace: A80US2V080B16X*AHRI reference: 21745604117.508.20152001.88EPA 4048186
7EH30BX-**+TDR+ furnace: A97US2V060B12X*AHRI reference: 21745604517.508.20152001.88EPA 4048190
7EH30BX-**+TDR+ furnace: A97US2V045B12S*AHRI reference: 21745605617.508.20151001.90EPA 4048200
7EH30AX-**+TDR+ furnace: A80UH1E040A12X*AHRI reference: 21745606317.507.80149001.50EPA 4048206
7EH30AX-**+TDR+ furnace: A80UH1E060A12X*AHRI reference: 21745606417.507.80149001.50EPA 4048207
7EH30AX-**+TDR+ furnace: A80UH1E070A12*AHRI reference: 21745606617.507.80145001.48EPA 4048211
7EH30BX-**+TDR+ furnace: A93UH1E045B12A*AHRI reference: 21745603117.508.50152001.88EPA 4048331
7E[C,U]24BX-**+TDR+ furnace: EFV08BCA*AHRI reference: 21754771117.508.50166001.98EPA 4469870
7EH36CX-**+TDR+ furnace: EFV16CCA*AHRI reference: 21754772917.508.10164002.08EPA 4469919
7E[C,U]36CX-**+TDR+ furnace: A98USMV090C20S*AHRI reference: 21832975517.508.20149001.94EPA 4584963
7E[C,U]36CX-**+TDR+ furnace: A97US2V090C20S*AHRI reference: 21832963417.508.20149001.94EPA 4585023

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →