Armstrong Air / AIR-SOURCE HEAT PUMP

A7HP14F42P-**A

7HP14F Series · A7HP14F Series · source records, page 3

64 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.5BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity41,000–42,000BTU/h

Each efficiency range summarizes published EPA records for A7HP14F42P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 64 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.564 / 64
EER2 · BTU/Wh12.5–13.264 / 64
HSPF2 · BTU/Wh7.8–8.264 / 64
Cooling capacity · BTU/h41,000–42,00064 / 64
Heating capacity at 47°F / 8.3°C · BTU/h39,000–40,50064 / 64
Heating capacity at 17°F / −8.3°C · BTU/h24,600–25,80064 / 64
Heating capacity at 5°F / −15°C · BTU/h19,000–20,80064 / 64
COP at 5°F / −15°C2–2.1464 / 64
Equipment / loop typeHP - Split System64 / 64
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)64 / 64
Compressor stagingSingle stage64 / 64
Connected capabilityNo64 / 64

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7E[C,U]48CX-**+TDR+ furnace: A98USMV110C20S*AHRI reference: 21574336115.207.80206002.10EPA 3652950
7E[C,U]48CX-**+TDR+ furnace: A97US2V090C12S*AHRI reference: 21574333915.207.80206002.08EPA 3653005
7E[C,U]48CX-**+TDR+ furnace: A97US2V090C16S*AHRI reference: 21574334015.207.80206002.10EPA 3653006
7E[C,U]48CX-**+TDR+ furnace: A97UH2E110C20S*AHRI reference: 21574334215.207.80206002.08EPA 3653007
7E[C,U]48CX-**+TDR+ furnace: A93UH1E090C12A*AHRI reference: 21574334515.207.80204002.10EPA 3653010
7AH1AV48PX-**AHRI reference: 21574333115.208.00196002.08EPA 3653018
7AH2AV42PXC**AHRI reference: 21574333415.208.10202002.14EPA 3653021
7AH2AV48PXC**AHRI reference: 21574333515.208.20204002.14EPA 3653022
7E[C,U]48CX-**+TDR+ furnace: A97UH2E090C16S*AHRI reference: 21574333815.207.80208002.10EPA 3653025
7E[C,U]49CX-**+TDR+ furnace: A97UH2E090C16S*AHRI reference: 21574336415.207.80199002.06EPA 3653027
7E[C,U]49CX-**+TDR+ furnace: A97US2V090C12S*AHRI reference: 21574336515.207.80196002.04EPA 3653028
7E[C,U]49CX-**+TDR+ furnace: A93UH1E090C16A*AHRI reference: 21574337215.207.80200002.06EPA 3653034
7E[C,U]49CX-**+TDR+ furnace: A96UH1E090C16S*AHRI reference: 21574337515.207.80200002.06EPA 3653036
7E[C,U]49CX-**+TDR+ furnace: A97US2V080C20X*AHRI reference: 21574338315.207.80199002.06EPA 3653065
7E[C,U]49CX-**+TDR+ furnace: A98USMV090C12S*AHRI reference: 21574338415.207.80197002.04EPA 3653066
7E[C,U]49CX-**+TDR+ furnace: A98USMV090C20S*AHRI reference: 21574338615.207.80198002.02EPA 3653068
7E[C,U]49CX-**+TDR+ furnace: A97US2V090C20S*AHRI reference: 21574336715.207.80200002.04EPA 3653162
7E[C,U]48CX-**+TDR+ furnace: 80G2UH110CV20*AHRI reference: 21677949315.207.80206002.08EPA 3992945
7E[C,U]48CX-**+TDR+ furnace: 97G2UH090CV12*AHRI reference: 21677949415.207.80206002.08EPA 3992946
7E[C,U]49CX-**+TDR+ furnace: 80G2UH110CV20*AHRI reference: 21677949615.207.80197002.04EPA 3992947

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →