Armstrong Air / AIR-SOURCE HEAT PUMP

A7HP14F24P-**A

7HP14F Series · A7HP14 Series · A7HP14F SERIES · A7HP14F Series · source records, page 6

132 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,800–24,000BTU/h

Each efficiency range summarizes published EPA records for A7HP14F24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 132 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16132 / 132
EER2 · BTU/Wh12–13.8132 / 132
HSPF2 · BTU/Wh7.8–8.2132 / 132
Cooling capacity · BTU/h22,800–24,000132 / 132
Heating capacity at 47°F / 8.3°C · BTU/h20,400–23,000132 / 132
Heating capacity at 17°F / −8.3°C · BTU/h12,900–14,700132 / 132
Heating capacity at 5°F / −15°C · BTU/h10,500–11,600132 / 132
COP at 5°F / −15°C1.96–2.2132 / 132
Equipment / loop typeHP - Split System132 / 132
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)132 / 132
Compressor stagingSingle stage132 / 132
Connected capabilityNo132 / 132

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH24BX-**+TDR+ furnace: A93UH1E070B12A*AHRI reference: 21571116015.208.10108002.00EPA 3646612 →
7EH24BX-**+TDR+ furnace: A96UH1E030B12S*AHRI reference: 21571116115.207.80106001.98EPA 3646613 →
7EH30BX-**+TDR+ furnace: A80UH1E080B16X*AHRI reference: 21571117915.208.00111002.06EPA 3646614 →
7EH30BX-**+TDR+ furnace: A97UH2E045B12S*AHRI reference: 21571118215.207.80112002.04EPA 3646617 →
7EH30BX-**+TDR+ furnace: A97US2V045B12S*AHRI reference: 21571118315.207.80111002.04EPA 3646618 →
7EH30BX-**+TDR+ furnace: A97UH2E070B12S*AHRI reference: 21571118415.207.80112002.04EPA 3646619 →
7EH30BX-**+TDR+ furnace: A80US2V080B16X*AHRI reference: 21571119415.207.80110002.04EPA 3646638 →
7EH30BX-**+TDR+ furnace: A97US2V040B12X*AHRI reference: 21571119715.207.80110002.04EPA 3646641 →
7ED30/36BX-**+TDR+ furnace: A80DF1E090B16*AHRI reference: 21571121015.208.20113002.10EPA 3646655 →
7ED30/36CX-**+TDR+ furnace: A97DF2E090C16S*AHRI reference: 21571121115.208.20113002.10EPA 3646656 →
7ED30/36CX-**+TDR+ furnace: A93DF1E090C16A*AHRI reference: 21571121215.208.20114002.12EPA 3646657 →
7ED30/36CX-**+TDR+ furnace: A96DF1E090C16S*AHRI reference: 21571121315.208.20113002.12EPA 3646658 →
7EH30AX-**+TDR+ furnace: A80UH1E045A12*AHRI reference: 21571117415.207.80109002.02EPA 3646860 →
7EH30AX-**+TDR+ furnace: A80UH1E070A12*AHRI reference: 21571117515.208.00110002.04EPA 3646861 →
7EH24AX-**+TDR+ furnace: A80US2V070A12L*AHRI reference: 21571114815.207.80108001.98EPA 3646866 →
7E[C,U]24AX-**+TDR+ furnace: 80G2UH070AV12*AHRI reference: 21677927715.207.80109002.02EPA 3992883 →
7E[C,U]24BX-**+TDR+ furnace: 80G2UH090BV16*AHRI reference: 21677927815.207.80108002.00EPA 3992884 →
7E[C,U]30BX-**+TDR+ furnace: 80G2UH090BV16*AHRI reference: 21677928215.207.80114002.14EPA 3992886 →
7E[C,U]30BX-**+TDR+ furnace: 97G2UH030BE08*AHRI reference: 21677928315.208.00114002.14EPA 3992887 →
7EH24AX-**+TDR+ furnace: 80G2UH070AV12*AHRI reference: 21677928615.207.80107001.96EPA 3992889 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →