A7HP14F18P-**A
A7HP14F Series
51 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for A7HP14F18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 51 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.5 | 51 / 51 |
| EER2 · BTU/Wh | 13–14.2 | 51 / 51 |
| HSPF2 · BTU/Wh | 7.8 | 51 / 51 |
| Cooling capacity · BTU/h | 18,000 | 51 / 51 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 17,500–18,000 | 51 / 51 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 10,500–11,200 | 51 / 51 |
| Heating capacity at 5°F / −15°C · BTU/h | 7,900–8,500 | 51 / 51 |
| COP at 5°F / −15°C | 1.86–2.06 | 51 / 51 |
| Equipment / loop type | HP - Split System | 51 / 51 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 51 / 51 |
| Compressor staging | Single stage | 51 / 51 |
| Connected capability | No | 51 / 51 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7EH30AX-**+TDR+ furnace: A80UH2E070A12*AHRI reference: 215708819 | 16.50 | 7.80 | 8200 | 2.00 | EPA 3646260 → |
7EH30AX-**+TDR+ furnace: A80UH1E045A12*AHRI reference: 215708820 | 16.50 | 7.80 | 8100 | 1.98 | EPA 3646261 → |
7EH30AX-**+TDR+ furnace: A80UH1E070A12*AHRI reference: 215708821 | 16.50 | 7.80 | 8100 | 1.98 | EPA 3646262 → |
7EH30AX-**+TDR+ furnace: A80US2V060A12X*AHRI reference: 215708822 | 16.50 | 7.80 | 8100 | 1.98 | EPA 3646263 → |
7EH30BX-**+TDR+ furnace: A80US2V090B16*AHRI reference: 215708840 | 16.50 | 7.80 | 8200 | 2.00 | EPA 3646917 → |
7EH30AX-**+TDR+ furnace: 80G2UH070AV12*AHRI reference: 216779144 | 16.50 | 7.80 | 8200 | 2.00 | EPA 3992829 → |
7EH24BX-**+TDR+ furnace: A97UH2E070B12S*AHRI reference: 215708801 | 16.00 | 7.80 | 8200 | 1.94 | EPA 3646104 → |
7EH24BX-**+TDR+ furnace: A97US2V070B12S*AHRI reference: 215708802 | 16.00 | 7.80 | 8300 | 1.96 | EPA 3646105 → |
7EH24BX-**+TDR+ furnace: A80UH1E070B12*AHRI reference: 215708803 | 16.00 | 7.80 | 8200 | 1.94 | EPA 3646107 → |
7EH24BX-**+TDR+ furnace: A93UH1E045B12A*AHRI reference: 215708805 | 16.00 | 7.80 | 8300 | 1.94 | EPA 3646109 → |
7EH24BX-**+TDR+ furnace: A93UH1E070B12A*AHRI reference: 215708806 | 16.00 | 7.80 | 8300 | 1.96 | EPA 3646110 → |
7AH1AE24PX-**AHRI reference: 215708747 | 16.00 | 7.80 | 8200 | 2.00 | EPA 3646151 → |
7AH1AV24PX-**AHRI reference: 215708748 | 16.00 | 7.80 | 8400 | 1.98 | EPA 3646152 → |
7AH2AV24PXC**AHRI reference: 215708749 | 16.00 | 7.80 | 8300 | 2.06 | EPA 3646153 → |
7EH24BX-**+TDR+ furnace: A80UH2E090B12*AHRI reference: 215708798 | 16.00 | 7.80 | 8300 | 1.96 | EPA 3646185 → |
7EH24BX-**+TDR+ furnace: A97UH2E045B12S*AHRI reference: 215708799 | 16.00 | 7.80 | 8300 | 1.96 | EPA 3646197 → |
7EH24AX-**+TDR+ furnace: A80UH2E070A12*AHRI reference: 215708792 | 16.00 | 7.80 | 8000 | 1.96 | EPA 3646239 → |
7EH24AX-**+TDR+ furnace: A80UH1E045A12*AHRI reference: 215708793 | 16.00 | 7.80 | 7900 | 1.94 | EPA 3646240 → |
7EH24AX-**+TDR+ furnace: A80UH1E070A12*AHRI reference: 215708794 | 16.00 | 7.80 | 8000 | 1.96 | EPA 3646241 → |
7EH24AX-**+TDR+ furnace: A80US2V070A12L*AHRI reference: 215708797 | 16.00 | 7.80 | 8000 | 1.92 | EPA 3646242 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →