Heating performance & equipment details
Ranges include the 141 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.7–20.5 | 141 / 141 |
| EER2 · BTU/Wh | 11–13.4 | 141 / 141 |
| HSPF2 · BTU/Wh | 7.8–9.6 | 141 / 141 |
| Cooling capacity · BTU/h | 45,000–48,000 | 141 / 141 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 42,500–51,000 | 141 / 141 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 34,200–44,000 | 141 / 141 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,000–39,500 | 141 / 141 |
| COP at 5°F / −15°C | 1.88–2.2 | 141 / 141 |
| Equipment / loop type | HP - Split System | 141 / 141 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 141 / 141 |
| Compressor staging | Continuously variable | 141 / 141 |
| Connected capability | No | 141 / 141 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7E[C,U]60CX-**+TDR+ furnace: A98USMV110C20S*Cold climate designationAHRI reference: 217120498 | 20.00 | 9.50 | 34200 | 2.10 | EPA 4006171 → |
7E[C,U]60CX-**+TDR+ furnace: A97US2V090C16S*Cold climate designationAHRI reference: 217120499 | 20.00 | 9.50 | 34400 | 2.10 | EPA 4006172 → |
7E[C,U]60CX-**+TDR+ furnace: A97US2V090C20S*Cold climate designationAHRI reference: 217120500 | 20.00 | 9.50 | 34400 | 2.10 | EPA 4006173 → |
7EH60DX-**+TDR+ furnace: A97US2V080C20X*AHRI reference: 217120479 | 20.00 | 8.50 | 31600 | 1.94 | EPA 4006251 → |
7E[C,U]60DX-**+TDR+ furnace: A80US2V135D20*Cold climate designationAHRI reference: 217120484 | 20.00 | 9.00 | 33800 | 2.00 | EPA 4006252 → |
7E[C,U]50/60CX-**+TDR+ furnace: A80UH2E110C16*AHRI reference: 217122086 | 20.00 | 8.20 | 29200 | 2.16 | EPA 4006294 → |
7E[C,U]60CX-**+TDR+ furnace: A80UH1E110C20*Cold climate designationAHRI reference: 217122110 | 20.00 | 9.60 | 34400 | 2.14 | EPA 4006316 → |
7E[C,U]60CX-**+TDR+ furnace: A93UH1E110C16A*Cold climate designationAHRI reference: 217122124 | 20.00 | 8.50 | 34000 | 2.12 | EPA 4006327 → |
7EH48CX-**+TDR+ furnace: A97US2V080C20X*Cold climate designationAHRI reference: 217120373 | 20.00 | 8.10 | 34000 | 1.96 | EPA 4011733 → |
7EH48CX-**+TDR+ furnace: A80US2V080B16X*Cold climate designationAHRI reference: 217120377 | 20.00 | 8.10 | 34200 | 1.96 | EPA 4011738 → |
7EH51CX-**+TDR+ furnace: A80US2V080C20X*Cold climate designationAHRI reference: 217446358 | 20.00 | 8.50 | 33200 | 2.04 | EPA 4044128 → |
7EH51CX-**+TDR+ furnace: A80US2V110C20*Cold climate designationAHRI reference: 217446361 | 20.00 | 8.50 | 33200 | 2.04 | EPA 4044130 → |
7EH51CX-**+TDR+ furnace: A98USMV090C16S*Cold climate designationAHRI reference: 217446365 | 20.00 | 8.50 | 33400 | 2.04 | EPA 4044133 → |
7EH51CX-**+TDR+ furnace: A98USMV110C20S*Cold climate designationAHRI reference: 217446368 | 20.00 | 8.50 | 33200 | 2.04 | EPA 4044136 → |
7EH51CX-**+TDR+ furnace: A97US2V090C16S*Cold climate designationAHRI reference: 217446372 | 20.00 | 8.50 | 33400 | 2.04 | EPA 4044139 → |
7EH51CX-**+TDR+ furnace: A80US2V090C20*Cold climate designationAHRI reference: 217446359 | 20.00 | 8.50 | 33200 | 2.04 | EPA 4044418 → |
7EH51CX-**+TDR+ furnace: A80US2V110C20L*Cold climate designationAHRI reference: 217446362 | 20.00 | 8.50 | 33200 | 2.04 | EPA 4044420 → |
7E[C,U]60CX-**+TDR+ furnace: EFV16CCA*Cold climate designationAHRI reference: 217493335 | 20.00 | 9.00 | 34200 | 2.12 | EPA 4433455 → |
7ED48CX-**+TDR+ furnace: EFV16CCA*AHRI reference: 217493339 | 20.00 | 8.00 | 32200 | 2.06 | EPA 4433459 → |
7EH51CX-**+TDR+ furnace: A97US2V110C16S*Cold climate designationAHRI reference: 217501222 | 20.00 | 8.50 | 33200 | 2.04 | EPA 4468431 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.