Heating performance & equipment details
Ranges include the 190 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–20 | 190 / 190 |
| EER2 · BTU/Wh | 11–12.2 | 190 / 190 |
| HSPF2 · BTU/Wh | 8.5–10.4 | 190 / 190 |
| Cooling capacity · BTU/h | 32,000–34,800 | 190 / 190 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,000–34,800 | 190 / 190 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 26,600–32,400 | 190 / 190 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,400–25,400 | 190 / 190 |
| COP at 5°F / −15°C | 1.84–2.46 | 190 / 190 |
| Equipment / loop type | HP - Split System | 190 / 190 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 190 / 190 |
| Compressor staging | Continuously variable | 190 / 190 |
| Connected capability | No | 190 / 190 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7E[C,U]30BX-**+TDR+ furnace: A93UH1E070B12A*AHRI reference: 217446256 | 18.00 | 10.40 | 22400 | 2.26 | EPA 4044541 → |
7EH30BX-**+TDR+ furnace: A80UH1E070B12*Cold climate designationAHRI reference: 217446287 | 18.00 | 9.00 | 22600 | 2.44 | EPA 4044562 → |
7EH42CX-**+TDR+ furnace: A97US2V110C16S*Cold climate designationAHRI reference: 217501220 | 18.00 | 9.80 | 22600 | 1.94 | EPA 4468429 → |
7E[C,U]36CX-**+TDR+ furnace: A98USMV110C20S*Cold climate designationAHRI reference: 218329769 | 18.00 | 8.50 | 21400 | 2.06 | EPA 4584949 → |
7E[C,U]36CX-**+TDR+ furnace: A97US2V090C20S*Cold climate designationAHRI reference: 218329664 | 18.00 | 8.50 | 21400 | 2.06 | EPA 4584995 → |
7E[C,U]36CX-**+TDR+ furnace: A97US2V110C20S*Cold climate designationAHRI reference: 218329660 | 18.00 | 8.50 | 21200 | 2.06 | EPA 4584999 → |
7E[C,U]36CX-**+TDR+ furnace: A80US2V110C20L*Cold climate designationAHRI reference: 218329658 | 18.00 | 8.50 | 21200 | 2.06 | EPA 4585001 → |
7E[C,U]36CX-**+TDR+ furnace: A97US2V080C16X*Cold climate designationAHRI reference: 218329656 | 18.00 | 8.50 | 21600 | 2.02 | EPA 4585003 → |
7EH30BX-**+TDR+ furnace: A97UH1E060B12*Cold climate designationAHRI reference: 218788074 | 18.00 | 9.00 | 22800 | 2.36 | EPA 4706612 → |
7E[C,U]36CX-**+TDR+ furnace: A97UH1E060B12*Cold climate designationAHRI reference: 218788073 | 18.00 | 8.50 | 21800 | 2.02 | EPA 4706613 → |
7E[C,U]36BX-**+TDR+ furnace: A97UH1E060B12*Cold climate designationAHRI reference: 218788072 | 18.00 | 8.50 | 22200 | 2.02 | EPA 4706614 → |
7E[C,U]30BX-**+TDR+ furnace: A97UH1E060B12*AHRI reference: 218788071 | 18.00 | 10.20 | 22800 | 2.22 | EPA 4706615 → |
7E[C,U]36BX-**+TDR+ furnace: A80UH1E090B16*Cold climate designationAHRI reference: 217122067 | 17.50 | 8.50 | 21600 | 2.08 | EPA 4006288 → |
7E[C,U]36BX-**+TDR+ furnace: A93UH1E030B12A*Cold climate designationAHRI reference: 217122068 | 17.50 | 8.50 | 22000 | 2.04 | EPA 4011645 → |
7E[C,U]36BX-**+TDR+ furnace: A96UH1E030B12S*Cold climate designationAHRI reference: 217122072 | 17.50 | 8.50 | 22000 | 2.04 | EPA 4011648 → |
7E[C,U]30BX-**+TDR+ furnace: A93UH1E030B12A*AHRI reference: 217446254 | 17.50 | 10.20 | 22600 | 2.24 | EPA 4044159 → |
7E[C,U]30BX-**+TDR+ furnace: A93UH1E045B12A*AHRI reference: 217446255 | 17.50 | 10.40 | 22600 | 2.24 | EPA 4044161 → |
7EH42CX-**+TDR+ furnace: A80US2V100C20X*Cold climate designationAHRI reference: 217446321 | 17.50 | 9.60 | 22600 | 1.94 | EPA 4044168 → |
7EH42CX-**+TDR+ furnace: A80US2V110C20*Cold climate designationAHRI reference: 217446322 | 17.50 | 9.60 | 22600 | 1.94 | EPA 4044169 → |
7EH42CX-**+TDR+ furnace: A97US2V080C20X*Cold climate designationAHRI reference: 217446325 | 17.50 | 9.60 | 22800 | 1.92 | EPA 4044171 → |