Armstrong Air / AIR-SOURCE HEAT PUMP

A7CP21V24P-**A

A7CP21V SERIES · A7CP21V Series · source records, page 4

136 published source records · source checked Sep 21, 2026

SEER2 range15.2–21BTU/Wh
HSPF2 range7.8–10.2BTU/Wh
Cooling capacity21,600–24,000BTU/h

Each efficiency range summarizes published EPA records for A7CP21V24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 136 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–21136 / 136
EER2 · BTU/Wh11.2–13.5136 / 136
HSPF2 · BTU/Wh7.8–10.2136 / 136
Cooling capacity · BTU/h21,600–24,000136 / 136
Heating capacity at 47°F / 8.3°C · BTU/h23,600–27,400136 / 136
Heating capacity at 17°F / −8.3°C · BTU/h18,700–22,400136 / 136
Heating capacity at 5°F / −15°C · BTU/h13,900–18,600136 / 136
COP at 5°F / −15°C1.7–2.3136 / 136
Equipment / loop typeHP - Split System136 / 136
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)136 / 136
Compressor stagingContinuously variable136 / 136
Connected capabilityNo136 / 136

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7E[C,U]30BX-**+TDR+ furnace: A98USMV070B12S*Cold climate designationAHRI reference: 21712043719.009.80176002.12EPA 4006115
7E[C,U]30BX-**+TDR+ furnace: A97US2V045B12S*Cold climate designationAHRI reference: 21712043819.009.80178002.10EPA 4006116
7E[C,U]30BX-**+TDR+ furnace: A97US2V070B12S*Cold climate designationAHRI reference: 21712043919.009.80177002.12EPA 4006117
7E[C,U]30BX-**+TDR+ furnace: A97UH2E070B12S*Cold climate designationAHRI reference: 21712205519.009.80178002.10EPA 4006280
7E[C,U]30AX-**+TDR+ furnace: A80UH1E070A12*Cold climate designationAHRI reference: 21712205619.009.80175002.10EPA 4006281
7E[C,U]30BX-**+TDR+ furnace: A80UH1E070B12*Cold climate designationAHRI reference: 21712205719.009.80174002.10EPA 4006282
7E[C,U]30BX-**+TDR+ furnace: A96UH1E070B12S*Cold climate designationAHRI reference: 21712206119.009.80177002.10EPA 4006284
7E[C,U]24AX-**+TDR+ furnace: A80UH1E040A12X*AHRI reference: 21744615519.008.50142001.74EPA 4043026
7E[C,U]24AX-**+TDR+ furnace: A80UH1E060A12X*AHRI reference: 21744615619.008.50142001.74EPA 4043027
7E[C,U]24AX-**+TDR+ furnace: A80UH2E070A12*AHRI reference: 21744615819.008.50143001.74EPA 4043029
7E[C,U]24BX-**+TDR+ furnace: A80UH2E090B12*AHRI reference: 21744616219.008.50143001.74EPA 4043033
7E[C,U]24BX-**+TDR+ furnace: A93UH1E045B12A*AHRI reference: 21744616419.008.50143001.74EPA 4043035
7E[C,U]24BX-**+TDR+ furnace: A97US2V060B12X*AHRI reference: 21744616819.008.50143001.74EPA 4043039
7E[C,U]24BX-**+TDR+ furnace: A97US2V045B12S*AHRI reference: 21744617119.008.50143001.74EPA 4043042
7E[C,U]24AX-**+TDR+ furnace: A80US2V060A12X*AHRI reference: 21744618319.008.50142001.76EPA 4044050
7E[C,U]24BX-**+TDR+ furnace: A93UH1E070B12A*AHRI reference: 21744618519.008.50142001.76EPA 4044052
7E[C,U]24BX-**+TDR+ furnace: A80US2V090B16*AHRI reference: 21744618819.008.50141001.76EPA 4044055
7E[C,U]24BX-**+TDR+ furnace: A80US2V090B16L*AHRI reference: 21744618919.008.50141001.76EPA 4044056
7E[C,U]24BX-**+TDR+ furnace: A98USMV070B12S*AHRI reference: 21744619019.008.50142001.76EPA 4044057
7E[C,U]24BX-**+TDR+ furnace: A97US2V070B12S*AHRI reference: 21744619119.008.50142001.76EPA 4044058

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →