Each efficiency range summarizes published EPA records for 4SHP18LX136P. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 161 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–19 | 161 / 161 |
| EER2 · BTU/Wh | 11–12.3 | 161 / 161 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 161 / 161 |
| Cooling capacity · BTU/h | 22,000–35,000 | 161 / 161 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,000–35,000 | 161 / 161 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,900–23,600 | 161 / 161 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,900–19,600 | 161 / 161 |
| COP at 5°F / −15°C | 1.82–2.22 | 161 / 161 |
| Equipment / loop type | HP - Split System | 161 / 161 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 161 / 161 |
| Compressor staging | Continuously variable | 161 / 161 |
| Connected capability | No | 161 / 161 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EAC4X24B+TDR+ furnace: A97UH2E070B12AHRI reference: 213927711 | 18.50 | 7.80 | 15600 | 2.03 | EPA 4010946 → |
EAH1P30B+TDR+TXV+ furnace: A97UH2E070B12AHRI reference: 213927715 | 18.50 | 8.50 | 15200 | 2.11 | EPA 4010950 → |
E*1P23B+TDR+TXV+ furnace: A97UH2E030B08AHRI reference: 214091898 | 18.50 | 8.10 | 10900 | 2.20 | EPA 4010975 → |
EA(C,U)1P24B+TDR+TXV+ furnace: A97UH2E030B08AHRI reference: 214091899 | 18.50 | 8.10 | 10900 | 2.15 | EPA 4010976 → |
EAC4X24B+TDR+ furnace: A97UH2E030B08AHRI reference: 214091901 | 18.50 | 8.10 | 10900 | 2.15 | EPA 4010978 → |
EAH1P30B+TDR+TXV+ furnace: A96UH1E070B12AHRI reference: 210740419 | 18.00 | 8.50 | 15300 | 2.03 | EPA 2447231 → |
EAH1P30B+TDR+TXV+ furnace: A96UH2E045B12AHRI reference: 210740423 | 18.00 | 8.50 | 15200 | 2.02 | EPA 2447232 → |
EAH1P30B+TDR+TXV+ furnace: A96UH2E070B12AHRI reference: 210740427 | 18.00 | 8.50 | 15200 | 2.02 | EPA 2447235 → |
ED1P30/36B+TDR+TXV+ furnace: A96DF1E045B12AHRI reference: 210738763 | 18.00 | 8.10 | 17900 | 2.04 | EPA 2447446 → |
E*1P23B+TDR+TXV+ furnace: A96UH1E045B12AHRI reference: 211632181 | 18.00 | 8.10 | 14600 | 1.90 | EPA 2447763 → |
E*1P23B+TDR+TXV+ furnace: A96UH1E070B12AHRI reference: 211632182 | 18.00 | 8.10 | 14600 | 1.90 | EPA 2447766 → |
BCE7E18M*4XAHRI reference: 210739939 | 18.00 | 8.50 | 14600 | 2.03 | EPA 2447893 → |
BCE5V18M*4XAHRI reference: 210739928 | 18.00 | 8.50 | 15200 | 2.04 | EPA 2447895 → |
ED1P24B+TDR+TXV+ furnace: A96DF1E045B12AHRI reference: 211632223 | 18.00 | 8.10 | 14900 | 1.83 | EPA 2448048 → |
BCE7E24M*4XAHRI reference: 213307162 | 18.00 | 8.50 | 15600 | 2.12 | EPA 2740079 → |
7EH30BX-0*+TDR+ furnace: A96UH1E070B12AHRI reference: 214730010 | 18.00 | 8.50 | 15300 | 2.03 | EPA 3492930 → |
7EH30BX-0*+TDR+ furnace: A96UH2E045B12AHRI reference: 214730011 | 18.00 | 8.50 | 15200 | 2.02 | EPA 3492933 → |
7EH30BX-0*+TDR+ furnace: A96UH2E070B12AHRI reference: 214730012 | 18.00 | 8.50 | 15200 | 2.02 | EPA 3492935 → |
7AH1AV18PX-0*AHRI reference: 215219043 | 18.00 | 8.50 | 15200 | 2.04 | EPA 3554749 → |
7AH2AE18PX-0*AHRI reference: 215219053 | 18.00 | 8.50 | 14600 | 2.03 | EPA 3554757 → |