4SHP18LX136P
4SHP18LX SERIES
161 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 4SHP18LX136P. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 161 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–19 | 161 / 161 |
| EER2 · BTU/Wh | 11–12.3 | 161 / 161 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 161 / 161 |
| Cooling capacity · BTU/h | 22,000–35,000 | 161 / 161 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,000–35,000 | 161 / 161 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,900–23,600 | 161 / 161 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,900–19,600 | 161 / 161 |
| COP at 5°F / −15°C | 1.82–2.22 | 161 / 161 |
| Equipment / loop type | HP - Split System | 161 / 161 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 161 / 161 |
| Compressor staging | Continuously variable | 161 / 161 |
| Connected capability | No | 161 / 161 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EAH1P30B+TDR+TXV+ furnace: A96US2V070B12AHRI reference: 210740435 | 19.00 | 8.50 | 14900 | 2.04 | EPA 2447236 → |
EAH1P30B+TDR+TXV+ furnace: A96US2V045B12AHRI reference: 210740431 | 19.00 | 8.50 | 15000 | 2.03 | EPA 2447240 → |
EAH1P30B+TDR+TXV+ furnace: A97US2V060B12XAHRI reference: 210740443 | 19.00 | 8.50 | 14900 | 2.02 | EPA 2447241 → |
EAH1P30B+TDR+TXV+ furnace: A97US2V040B12XAHRI reference: 210740439 | 19.00 | 8.50 | 14900 | 2.02 | EPA 2447242 → |
EA(C;U)1P24B+TDR+TXV+ furnace: A96US2V070B12AHRI reference: 210740095 | 19.00 | 7.80 | 15200 | 1.94 | EPA 2447428 → |
EA(C;U)1P24B+TDR+TXV+ furnace: A97US2V040B12XAHRI reference: 210740099 | 19.00 | 7.80 | 15300 | 1.93 | EPA 2447429 → |
E*1P23B+TDR+TXV+ furnace: A96US2V045B12AHRI reference: 210740009 | 19.00 | 8.10 | 14300 | 1.89 | EPA 2447503 → |
E*1P23B+TDR+TXV+ furnace: A96US2V070B12AHRI reference: 210740013 | 19.00 | 8.10 | 14200 | 1.91 | EPA 2447504 → |
E*1P23B+TDR+TXV+ furnace: A97US2V040B12XAHRI reference: 210740017 | 19.00 | 8.10 | 14300 | 1.90 | EPA 2447509 → |
E*1P23B+TDR+TXV+ furnace: A97USMV070B12AHRI reference: 211632183 | 19.00 | 8.10 | 14200 | 1.90 | EPA 2447767 → |
EAC4X30B+TDR+ furnace: A97USMV070B12AHRI reference: 211632213 | 19.00 | 8.10 | 14800 | 1.97 | EPA 2447774 → |
EA(C,U)1P30B+TDR+TXV+ furnace: A97USMV070B12AHRI reference: 211632198 | 19.00 | 8.10 | 14800 | 1.97 | EPA 2447778 → |
BCE7E30M*4XAHRI reference: 210739943 | 19.00 | 8.50 | 15500 | 2.17 | EPA 2447889 → |
BCE7S30M*4XAHRI reference: 210739951 | 19.00 | 8.50 | 15400 | 2.15 | EPA 2447891 → |
BCE7S24M*4XAHRI reference: 210739947 | 19.00 | 8.50 | 15400 | 2.08 | EPA 2447892 → |
ED1P24B+TDR+TXV+ furnace: A97DSMV070B12AHRI reference: 211632228 | 19.00 | 8.10 | 14700 | 1.82 | EPA 2448050 → |
EAC4X24B+TDR+ furnace: A96US2V045B12AHRI reference: 210740258 | 19.00 | 7.80 | 15300 | 1.93 | EPA 2448058 → |
EAC4X24B+TDR+ furnace: A97US2V060B12XAHRI reference: 210740270 | 19.00 | 7.80 | 15200 | 1.92 | EPA 2448063 → |
EAC4X24B+TDR+ furnace: A97US2V040B12XAHRI reference: 210740266 | 19.00 | 7.80 | 15300 | 1.93 | EPA 2448064 → |
EAC4X24B+TDR+ furnace: A96US2V070B12AHRI reference: 210740262 | 19.00 | 7.80 | 15200 | 1.94 | EPA 2448065 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →