Armstrong Air / AIR-SOURCE HEAT PUMP

4SHP17LE148P-**A

4HSP17LE Series · 4SHP17LE SERIES · 4SHP17LE Series · 4SHP17LE1 Series · source records, page 2

226 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.8BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE148P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 226 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.8226 / 226
EER2 · BTU/Wh12.5–13226 / 226
HSPF2 · BTU/Wh8–8.5226 / 226
Cooling capacity · BTU/h46,000–48,000226 / 226
Heating capacity at 47°F / 8.3°C · BTU/h44,500–47,000226 / 226
Heating capacity at 17°F / −8.3°C · BTU/h30,000–31,800226 / 226
Heating capacity at 5°F / −15°C · BTU/h24,200–26,000226 / 226
COP at 5°F / −15°C2.16–2.38226 / 226
Equipment / loop typeHP - Split System226 / 226
Refrigerant / source-reported GWPR-410A (GWP:2088)226 / 226
Compressor stagingSingle stage226 / 226
Connected capabilityNo226 / 226

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC49CX-0*+TDR+ furnace: A80US2V080C20XAHRI reference: 21471457615.608.10254002.28EPA 3487369
7EC60CX-0*+TDR+ furnace: A80UH2E110C16AHRI reference: 21471461515.608.30252002.36EPA 3489071
7EC60CX-0*+TDR+ furnace: A80UH2E110C20AHRI reference: 21471461615.608.30252002.38EPA 3489072
7EH51CX-0*+TDR+ furnace: A80UH1E090C20AHRI reference: 21471449115.608.30252002.30EPA 3489084
7EH51CX-0*+TDR+ furnace: A80US2V080C20XAHRI reference: 21471449715.608.30254002.32EPA 3489139
7EC60CX-0*+TDR+ furnace: A80UH1E090C20AHRI reference: 21471462415.608.10252002.38EPA 3489168
7EC60CX-0*+TDR+ furnace: A80US2V100C20XAHRI reference: 21471463315.608.30254002.38EPA 3489198
7EC49CX-0*+TDR+ furnace: A80UH1E090C20AHRI reference: 21471456915.608.10250002.26EPA 3489228
7EC48CX-0*+TDR+ furnace: A80UH2E110C20AHRI reference: 21471453315.608.10242002.20EPA 3489237
EA(C;U)1P49C+TDR+TXV+ furnace: A80UH2E110C20AHRI reference: 21032911215.408.10254002.26EPA 2456092
EA(C;U)1P60C+TDR+TXV+ furnace: A80US2V110C20LAHRI reference: 21032914215.408.30254002.32EPA 2456101
BCE7E48M*4XAHRI reference: 21032909415.408.50244002.34EPA 2456214
EA(C;U)1P49C+TDR+TXV+ furnace: A80UH2E110C16AHRI reference: 21032911715.408.10254002.26EPA 2456215
EA(C;U)1P60C+TDR+TXV+ furnace: A93UH1E110C16AHRI reference: 21032913315.408.10252002.36EPA 2456254
EAC4X49C+TDR+ furnace: A80US2V100C20XAHRI reference: 21166272215.408.10254002.26EPA 2456598
EAC4X48C+TDR+ furnace: A80UH1E090C20AHRI reference: 21166270215.408.10244002.22EPA 2456638
EAC4X48C+TDR+ furnace: A93UH1E110C20AHRI reference: 21166270415.408.10244002.18EPA 2456644
EAC4X48C+TDR+ furnace: A80US2V100C20XAHRI reference: 21166270715.408.10244002.20EPA 2456928
EAC4X48C+TDR+ furnace: A80US2V080C20XAHRI reference: 21166270615.408.10244002.24EPA 2456930
EA(C;U)1P60C+TDR+TXV+ furnace: A80UH1E110C20AHRI reference: 21032913015.408.30254002.34EPA 2457125

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →