Armstrong Air / AIR-SOURCE HEAT PUMP

4SHP17LE142P-**A

4HSP17LE Series · 4SHP17 SERIES · 4SHP17L SERIES · 4SHP17LE SERIES · 4SHP17LE Series · 4SHP17LE1 Series · source records, page 2

85 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range7.8–8.3BTU/Wh
Cooling capacity40,000–42,000BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE142P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 85 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.685 / 85
EER2 · BTU/Wh12.5–1385 / 85
HSPF2 · BTU/Wh7.8–8.385 / 85
Cooling capacity · BTU/h40,000–42,00085 / 85
Heating capacity at 47°F / 8.3°C · BTU/h37,600–42,00085 / 85
Heating capacity at 17°F / −8.3°C · BTU/h25,000–27,60085 / 85
Heating capacity at 5°F / −15°C · BTU/h10,400–22,00085 / 85
COP at 5°F / −15°C2–2.285 / 85
Equipment / loop typeHP - Split System85 / 85
Refrigerant / source-reported GWPR-410A (GWP:2088)85 / 85
Compressor stagingSingle stage85 / 85
Connected capabilityNo85 / 85

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X49C+TDR+ furnace: A80UH2E110C16AHRI reference: 21166266915.407.80196002.08EPA 2458931
EAC4X49C+TDR+ furnace: A80UH2E110C20AHRI reference: 21166267015.407.80199002.08EPA 2458932
EAC4X49C+TDR+ furnace: A80UH1E090C20AHRI reference: 21166267315.407.80198002.12EPA 2458936
EA(C;U)1P49C+TDR+TXV+ furnace: A80UH2E110C20AHRI reference: 21032918815.407.80199002.08EPA 2459104
EA(C;U)1P49C+TDR+TXV+ furnace: A80UH1E110C20AHRI reference: 21032918515.407.80198002.10EPA 2459336
EA(C;U)1P49C+TDR+TXV+ furnace: A80UH1E090C20AHRI reference: 21032918415.407.80198002.12EPA 2459349
EAD4X-48C+TDR+ furnace: A80DS2V110C20AHRI reference: 21326486615.408.30220002.14EPA 2839806
7EH42CX-0*+TDR+ furnace: A80US2V080C20XAHRI reference: 21471430115.407.80202002.04EPA 3487377
7EH42CX-0*+TDR+ furnace: A80US2V100C20XAHRI reference: 21471430315.407.80200002.00EPA 3487410
7EC49CX-0*+TDR+ furnace: A80UH2E110C16AHRI reference: 21471441915.407.80196002.08EPA 3487578
7EH48CX-0*+TDR+ furnace: A80US2V100C20XAHRI reference: 21471434915.407.80202002.04EPA 3487720
7EC48CX-0*+TDR+ furnace: A80UH1E110C20AHRI reference: 21471440015.407.80196002.10EPA 3487826
7EH42BX-0*+TDR+ furnace: A80UH2E090B12AHRI reference: 21471426815.407.80199002.10EPA 3487843
7EH42BX-0*+TDR+ furnace: A80UH1E070B12AHRI reference: 21471427315.407.80202002.12EPA 3487847
7EH42BX-0*+TDR+ furnace: A80UH1E090B16AHRI reference: 21471427415.407.80200002.12EPA 3487848
7EC48CX-0*+TDR+ furnace: A93UH1E110C20AHRI reference: 21471440415.407.80199002.10EPA 3487957
7EC48CX-0*+TDR+ furnace: A93UH1E110C16AHRI reference: 21471440315.407.80196002.10EPA 3487958
7EC49CX-0*+TDR+ furnace: A80UH2E110C20AHRI reference: 21471442015.407.80199002.08EPA 3489114
7EC49CX-0*+TDR+ furnace: A80UH1E090C20AHRI reference: 21471442815.407.80198002.12EPA 3489144
7EC49CX-0*+TDR+ furnace: A80UH1E110C20AHRI reference: 21471442915.407.80198002.10EPA 3489146

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →