Armstrong Air / AIR-SOURCE HEAT PUMP

4SHP17LE136P-**A

4HSP17LE Series · 4SHP17 SERIES · 4SHP17L SERIES · 4SHP17LE SERIES · 4SHP17LE Series · 4SHP17LE1 Series · source records, page 16

454 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE136P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 454 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8454 / 454
EER2 · BTU/Wh12.2–14454 / 454
HSPF2 · BTU/Wh7.8–8.7454 / 454
Cooling capacity · BTU/h34,800–36,000454 / 454
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000454 / 454
Heating capacity at 17°F / −8.3°C · BTU/h21,400–24,000454 / 454
Heating capacity at 5°F / −15°C · BTU/h16,800–19,300454 / 454
COP at 5°F / −15°C2.06–2.36454 / 454
Equipment / loop typeHP - Split System454 / 454
Refrigerant / source-reported GWPR-410A (GWP:2088)454 / 454
Compressor stagingSingle stage454 / 454
Connected capabilityNo454 / 454

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P36B+TDR+TXV+ furnace: A96UH1E070B12AHRI reference: 21166259215.807.80170002.08EPA 2456591
EA(C;U)1P36B+TDR+TXV+ furnace: A96UH1E030B12AHRI reference: 21166259115.807.80173002.10EPA 2456592
EA(C;U)1P36B+TDR+TXV+ furnace: A93UH1E045B12AHRI reference: 21166258915.807.80170002.08EPA 2456595
EA(C;U)1P36B+TDR+TXV+ furnace: A97US2V040B12XAHRI reference: 21166259615.807.80174002.12EPA 2456607
EA(C;U)1P36B+TDR+TXV+ furnace: A97USMV070B12AHRI reference: 21166259815.807.80174002.12EPA 2456609
EA(C;U)1P36B+TDR+TXV+ furnace: A97US2V060B12XAHRI reference: 21166259715.807.80174002.12EPA 2456612
EAC4X50/60C+TDR+ furnace: A80US2V110C20LAHRI reference: 21166265915.807.80174002.10EPA 2456935
EAC4X50/60C+TDR+ furnace: A80US2V110C20AHRI reference: 21166265815.807.80174002.10EPA 2456936
EAC4X50/60C+TDR+ furnace: A97US2V080C20XAHRI reference: 21166266115.807.80174002.10EPA 2456937
EAC4X50/60C+TDR+ furnace: A97USMV090C20AHRI reference: 21166266415.807.80176002.12EPA 2456947
BCE5E42M*4XAHRI reference: 21117081515.808.10173002.20EPA 2457218
EAC4X50/60C+TDR+ furnace: A80US2V090C20AHRI reference: 21166265615.807.80174002.08EPA 2457372
EAC4X36A+TDR+ furnace: A80US2V070A12AHRI reference: 21166261515.807.80174002.10EPA 2457601
EAC4X36A+TDR+ furnace: A80US2V070A12LAHRI reference: 21166261615.807.80174002.10EPA 2457602
EAC4X36A+TDR+ furnace: A80UH1E040A12XAHRI reference: 21166260815.807.80170002.08EPA 2457829
EAC4X36A+TDR+ furnace: A80UH1E060A12XAHRI reference: 21166260915.807.80170002.08EPA 2457830
BCE5V36M*4XAHRI reference: 21032921415.808.10174002.20EPA 2458017
BCE7S36M*4XAHRI reference: 21032921615.808.50186002.32EPA 2458025
EAC4X36B+TDR+ furnace: A97US2V040B12XAHRI reference: 21166263415.807.80174002.12EPA 2458056
EAC4X36B+TDR+ furnace: A97US2V060B12XAHRI reference: 21166263515.807.80174002.12EPA 2458057

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →