Armstrong Air / AIR-SOURCE HEAT PUMP

4SHP17LE130P-**A

4HSP17LE Series · 4SHP17 SERIES · 4SHP17L SERIES · 4SHP17LE SERIES · 4SHP17LE Series · 4SHP17LE1 Series · source records, page 5

333 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE130P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 333 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2333 / 333
EER2 · BTU/Wh12.2–13.5333 / 333
HSPF2 · BTU/Wh7.8–8.6333 / 333
Cooling capacity · BTU/h28,200–30,600333 / 333
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000333 / 333
Heating capacity at 17°F / −8.3°C · BTU/h17,200–19,600333 / 333
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400333 / 333
COP at 5°F / −15°C1.96–2.38333 / 333
Equipment / loop typeHP - Split System333 / 333
Refrigerant / source-reported GWPR-410A (GWP:2088)333 / 333
Compressor stagingSingle stage333 / 333
Connected capabilityNo333 / 333

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC36BX-0*+TDR+ furnace: A80UH1E070B12AHRI reference: 21471402416.008.10143002.26EPA 3487683
7EC36AX-0*+TDR+ furnace: A80UH2E070A12AHRI reference: 21471401016.008.10143002.26EPA 3487684
7EC36AX-0*+TDR+ furnace: A80UH1E045A12AHRI reference: 21471401116.008.10144002.28EPA 3487804
7EC36AX-0*+TDR+ furnace: A80UH1E070A12AHRI reference: 21471401216.008.10144002.28EPA 3487805
7EC30BX-0*+TDR+ furnace: A80UH2E090B16AHRI reference: 21471398716.008.00142002.22EPA 3487817
7EC36BX-0*+TDR+ furnace: A93UH1E070B12AHRI reference: 21471402816.008.10144002.28EPA 3487878
7EC36BX-0*+TDR+ furnace: A80US2V090B16AHRI reference: 21471403416.008.10144002.28EPA 3487889
7EC36BX-0*+TDR+ furnace: A97US2V070B12S*AHRI reference: 21471402316.008.10145002.28EPA 3491679
7EC36BX-0*+TDR+ furnace: A98USMV070B12AHRI reference: 21478040916.008.10145002.28EPA 3543191
7AH1AE36PX-0*AHRI reference: 21486594016.008.50132002.14EPA 3553874
BCE5V36M*4XAHRI reference: 21117439415.808.10134002.16EPA 2454784
EA(C;U)1P36A+TDR+TXV+ furnace: A80UH1E060A12XAHRI reference: 21032938515.808.00144002.26EPA 2456078
EA(C;U)1P36A+TDR+TXV+ furnace: A80US2V070A12AHRI reference: 21032938815.808.10144002.26EPA 2456211
EA(C;U)1P36A+TDR+TXV+ furnace: A80UH1E040A12XAHRI reference: 21032938415.808.00144002.26EPA 2456263
EA(C;U)1P36A+TDR+TXV+ furnace: A93UH1E030B12AHRI reference: 21032940115.808.10142002.26EPA 2456296
EA(C;U)1P30A+TDR+TXV+ furnace: A80UH1E045A12AHRI reference: 21032935215.808.00141002.20EPA 2456304
BCE7E30M*4XAHRI reference: 21032934915.808.50147002.36EPA 2456367
EA(C;U)1P30A+TDR+TXV+ furnace: A80UH2E045A12AHRI reference: 21032935615.808.10143002.24EPA 2456369
EA(C;U)1P36A+TDR+TXV+ furnace: A93UH1E045B12AHRI reference: 21032939315.808.10143002.26EPA 2456370
EAC4X30B+TDR+ furnace: A80US2V080B16XAHRI reference: 21166254315.808.10143002.20EPA 2456615

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →