Armstrong Air / AIR-SOURCE HEAT PUMP

4SHP17LE130P-**A

4HSP17LE Series · 4SHP17 SERIES · 4SHP17L SERIES · 4SHP17LE SERIES · 4SHP17LE Series · 4SHP17LE1 Series · source records, page 17

333 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE130P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 333 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2333 / 333
EER2 · BTU/Wh12.2–13.5333 / 333
HSPF2 · BTU/Wh7.8–8.6333 / 333
Cooling capacity · BTU/h28,200–30,600333 / 333
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000333 / 333
Heating capacity at 17°F / −8.3°C · BTU/h17,200–19,600333 / 333
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400333 / 333
COP at 5°F / −15°C1.96–2.38333 / 333
Equipment / loop typeHP - Split System333 / 333
Refrigerant / source-reported GWPR-410A (GWP:2088)333 / 333
Compressor stagingSingle stage333 / 333
Connected capabilityNo333 / 333

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X30B+TDR+ furnace: A80UH1E080B16XAHRI reference: 21166252815.208.00147002.16EPA 2457610
EA(C;U)1P30B+TDR+TXV+ furnace: A80UH1E080B16XAHRI reference: 21166246015.208.00147002.16EPA 2458924
EAH1P36C*+TDR+TXV+ furnace: A97USMV110C20AHRI reference: 21173622515.208.50152002.22EPA 2464105
EAH1P30A*+TDR+TXV+ furnace: A80UH1E040A12XAHRI reference: 21173578815.207.80141001.96EPA 2468389
EAH1P30A*+TDR+TXV+ furnace: A80UH1E060A12XAHRI reference: 21173580115.207.80141001.96EPA 2468396
EAH1P36C*+TDR+TXV+ furnace: A98USMV110C20AHRI reference: 21380529215.208.50152002.22EPA 2856802
EAH1P36C+TDR+TXV+ furnace: A97US2V110C20SAHRI reference: 21407454815.208.50152002.22EPA 3391950
7EH30AX-0*+TDR+ furnace: A80UH1E060A12XAHRI reference: 21471390415.207.80141001.96EPA 3487465
7EH36CX-0*+TDR+ furnace: A97US2V110C20S*AHRI reference: 21471394315.208.50152002.22EPA 3487558
7EC30BX-0*+TDR+ furnace: A80UH1E080B16XAHRI reference: 21471398515.208.00147002.16EPA 3487620
7EH36CX-0*+TDR+ furnace: A97USMV110C20AHRI reference: 21471396215.208.50152002.22EPA 3487789
7EH30AX-0*+TDR+ furnace: A80UH1E040A12XAHRI reference: 21471390315.207.80141001.96EPA 3491590
7EH36CX-0*+TDR+ furnace: A98USMV110C20AHRI reference: 21478040715.208.50152002.22EPA 3543323

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →