SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE118P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 331 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8331 / 331
EER2 · BTU/Wh12.2–14331 / 331
HSPF2 · BTU/Wh7.8–8.5331 / 331
Cooling capacity · BTU/h18,000331 / 331
Heating capacity at 47°F / 8.3°C · BTU/h16,000–18,000331 / 331
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100331 / 331
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700331 / 331
COP at 5°F / −15°C1.9–2.16331 / 331
Equipment / loop typeHP - Split System331 / 331
Refrigerant / source-reported GWPR-410A (GWP:2088)331 / 331
Compressor stagingSingle stage331 / 331
Connected capabilityNo331 / 331

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P30A+TDR+TXV+ furnace: A98USMV070B12AHRI reference: 21380502916.808.0078002.00EPA 2856912
EAH1P30B*+TDR+TXV+ furnace: A98USMV070B12AHRI reference: 21380527416.808.0078002.00EPA 2857956
EA(C;U)1P30B+TDR+TXV+ furnace: A97US2V070B12SAHRI reference: 21407443716.808.0078002.00EPA 3391936
EAH1P30B+TDR+TXV+ furnace: A97US2V070B12SAHRI reference: 21407444116.808.0078002.00EPA 3391940
EAC4X30B+TDR+ furnace: A97US2V070B12SAHRI reference: 21407444516.808.0078002.00EPA 3391960
7EC30BX-0*+TDR+ furnace: A80UH1E070B12AHRI reference: 21471376616.807.8077001.98EPA 3486775
7EH24BX-0*+TDR+ furnace: A80US2V080B16XAHRI reference: 21471367316.808.1084002.10EPA 3487184
7EH24BX-0*+TDR+ furnace: A80US2V090B12AHRI reference: 21471367416.808.1084002.08EPA 3487189
7EH30BX-0*+TDR+ furnace: A80UH2E090B12AHRI reference: 21471368116.808.0076002.00EPA 3487246
7EC30AX-0*+TDR+ furnace: A80UH2E070A12AHRI reference: 21471375216.808.0076001.98EPA 3487267
7EC30AX-0*+TDR+ furnace: A80UH1E045A12AHRI reference: 21471375316.807.8077002.00EPA 3487269
7EC30BX-0*+TDR+ furnace: A97US2V070B12S*AHRI reference: 21471376516.808.0078002.00EPA 3487353
7EH30BX-0*+TDR+ furnace: A97US2V070B12S*AHRI reference: 21471368616.808.0078002.00EPA 3487355
7EH30BX-0*+TDR+ furnace: A80UH1E070B12AHRI reference: 21471368716.808.0077002.04EPA 3487356
7EC30BX-0*+TDR+ furnace: A80US2V090B12AHRI reference: 21471377516.808.1080002.02EPA 3487380
7EC30BX-0*+TDR+ furnace: A97US2V040B12XAHRI reference: 21471377716.808.0078002.00EPA 3487384
7EC30BX-0*+TDR+ furnace: A97US2V060B12XAHRI reference: 21471377816.808.0078002.00EPA 3487386
7EC30BX-0*+TDR+ furnace: A97USMV070B12AHRI reference: 21471377916.808.0078002.00EPA 3487388
7EC30BX-0*+TDR+ furnace: A80US2V080B16XAHRI reference: 21471377416.808.1078001.98EPA 3487425
7EH30BX-0*+TDR+ furnace: A93UH1E045B12AHRI reference: 21471369016.808.0079002.02EPA 3487478

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.