4SHP17LE118P-**A
4HSP17LE Series · 4SHP17 SERIES · 4SHP17LE SERIES · 4SHP17LE Series · 4SHP17LE1 Series · source records, page 14
331 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 4SHP17LE118P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 331 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.8 | 331 / 331 |
| EER2 · BTU/Wh | 12.2–14 | 331 / 331 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 331 / 331 |
| Cooling capacity · BTU/h | 18,000 | 331 / 331 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 16,000–18,000 | 331 / 331 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 10,200–12,100 | 331 / 331 |
| Heating capacity at 5°F / −15°C · BTU/h | 7,500–9,700 | 331 / 331 |
| COP at 5°F / −15°C | 1.9–2.16 | 331 / 331 |
| Equipment / loop type | HP - Split System | 331 / 331 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 331 / 331 |
| Compressor staging | Single stage | 331 / 331 |
| Connected capability | No | 331 / 331 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7EC24BX-0*+TDR+ furnace: A80US2V090B16AHRI reference: 214713744 | 16.00 | 8.10 | 8500 | 2.06 | EPA 3487093 → |
7EC30BX-0*+TDR+ furnace: A96UH1E030B12AHRI reference: 214713771 | 16.00 | 7.80 | 7800 | 1.96 | EPA 3487100 → |
7EC24AX-0*+TDR+ furnace: A80UH2E045A12AHRI reference: 214713720 | 16.00 | 8.10 | 8400 | 2.06 | EPA 3487160 → |
7EC24AX-0*+TDR+ furnace: A80US2V070A12AHRI reference: 214713725 | 16.00 | 8.10 | 8500 | 2.06 | EPA 3487169 → |
7EH24BX-0*+TDR+ furnace: A96UH1E045B12AHRI reference: 214713671 | 16.00 | 8.10 | 8200 | 2.06 | EPA 3487181 → |
7EH24BX-0*+TDR+ furnace: A96UH1E070B12AHRI reference: 214713672 | 16.00 | 8.10 | 8200 | 2.06 | EPA 3487183 → |
7EH24BX-0*+TDR+ furnace: A80US2V090B16AHRI reference: 214713675 | 16.00 | 8.10 | 8700 | 2.08 | EPA 3487190 → |
7EC30AX-0*+TDR+ furnace: A80UH1E040A12XAHRI reference: 214713749 | 16.00 | 7.80 | 7500 | 1.92 | EPA 3487205 → |
7EH24BX-0*+TDR+ furnace: A97UH2E070B12AHRI reference: 214713663 | 16.00 | 8.10 | 8300 | 2.08 | EPA 3487220 → |
7EC24BX-0*+TDR+ furnace: A93UH1E030B12AHRI reference: 214713736 | 16.00 | 8.10 | 8400 | 2.08 | EPA 3487224 → |
7EH24BX-0*+TDR+ furnace: A93UH1E030B12AHRI reference: 214713667 | 16.00 | 8.10 | 8400 | 2.08 | EPA 3487226 → |
7EC24BX-0*+TDR+ furnace: A96UH1E045B12AHRI reference: 214713740 | 16.00 | 8.00 | 8200 | 2.04 | EPA 3487230 → |
7EC24BX-0*+TDR+ furnace: A96UH1E070B12AHRI reference: 214713741 | 16.00 | 8.00 | 8200 | 2.08 | EPA 3487232 → |
7ED30/36BX-0*+TDR+ furnace: A97DF2E045B12AHRI reference: 214713702 | 16.00 | 8.30 | 8900 | 2.08 | EPA 3487235 → |
7ED30/36BX-0*+TDR+ furnace: A97DF2E070B16AHRI reference: 214713704 | 16.00 | 8.30 | 8900 | 2.08 | EPA 3487239 → |
7EC30AX-0*+TDR+ furnace: A80UH2E045A12AHRI reference: 214713751 | 16.00 | 7.80 | 7900 | 1.98 | EPA 3487265 → |
7ED30/36BX-0*+TDR+ furnace: A80DF1E070B12AHRI reference: 214713706 | 16.00 | 8.30 | 8700 | 2.06 | EPA 3487289 → |
7EH24AX-0*+TDR+ furnace: A80UH1E040A12XAHRI reference: 214713649 | 16.00 | 7.80 | 8100 | 2.00 | EPA 3487394 → |
7EH24AX-0*+TDR+ furnace: A80UH1E060A12XAHRI reference: 214713650 | 16.00 | 7.80 | 8100 | 2.00 | EPA 3487395 → |
7EH24AX-0*+TDR+ furnace: A80UH2E045A12AHRI reference: 214713651 | 16.00 | 8.10 | 8200 | 2.02 | EPA 3487397 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.