Armstrong Air / AIR-SOURCE HEAT PUMP

4SHP17LE118P-**A

4HSP17LE Series · 4SHP17 SERIES · 4SHP17LE SERIES · 4SHP17LE Series · 4SHP17LE1 Series · source records, page 12

331 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE118P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 331 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8331 / 331
EER2 · BTU/Wh12.2–14331 / 331
HSPF2 · BTU/Wh7.8–8.5331 / 331
Cooling capacity · BTU/h18,000331 / 331
Heating capacity at 47°F / 8.3°C · BTU/h16,000–18,000331 / 331
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100331 / 331
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700331 / 331
COP at 5°F / −15°C1.9–2.16331 / 331
Equipment / loop typeHP - Split System331 / 331
Refrigerant / source-reported GWPR-410A (GWP:2088)331 / 331
Compressor stagingSingle stage331 / 331
Connected capabilityNo331 / 331

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P24B+TDR+TXV+ furnace: A93UH1E030B12AHRI reference: 21166223816.008.1084002.08EPA 2456653
EA(C;U)1P24B+TDR+TXV+ furnace: A93UH1E045B12AHRI reference: 21166223916.008.0082002.06EPA 2456656
EA(C;U)1P24B+TDR+TXV+ furnace: A96UH1E070B12AHRI reference: 21166224316.008.0082002.08EPA 2456657
EA(C;U)1P24B+TDR+TXV+ furnace: A96UH1E045B12AHRI reference: 21166224216.008.0082002.04EPA 2456659
BCE5E24M*4XAHRI reference: 21117081116.008.1085002.14EPA 2457215
EA(C;U)1P24A+TDR+TXV+ furnace: A93UH1E030B12AHRI reference: 21032959316.008.1084002.08EPA 2457276
BCE5V18M*4XAHRI reference: 21032957316.008.1082002.08EPA 2457308
EA(C;U)1P30A+TDR+TXV+ furnace: A80UH1E040A12XAHRI reference: 21032960516.007.8075001.92EPA 2457315
EAC4X24B+TDR+ furnace: A80US2V090B16AHRI reference: 21166231416.008.1085002.06EPA 2457382
EAC4X24B+TDR+ furnace: A93UH1E030B12AHRI reference: 21166230616.008.1084002.08EPA 2457587
EAC4X24B+TDR+ furnace: A93UH1E045B12AHRI reference: 21166230716.008.0082002.06EPA 2457589
EAC4X24B+TDR+ furnace: A96UH1E045B12AHRI reference: 21166231016.008.0082002.04EPA 2457592
EAC4X24B+TDR+ furnace: A96UH1E070B12AHRI reference: 21166231116.008.0082002.08EPA 2457593
EAC4X30B+TDR+ furnace: A96UH1E030B12AHRI reference: 21166233816.007.8078001.96EPA 2457616
EAC4X30A+TDR+ furnace: A80UH1E040A12XAHRI reference: 21166231816.007.8075001.92EPA 2457837
EAC4X30A+TDR+ furnace: A80UH1E060A12XAHRI reference: 21166231916.007.8075001.92EPA 2457838
EAC4X30A+TDR+ furnace: A80UH2E045A12AHRI reference: 21166232016.007.8079001.98EPA 2457839
EA(C;U)1P30A+TDR+TXV+ furnace: A80UH1E060A12XAHRI reference: 21032960616.007.8075001.92EPA 2458296
EA(C;U)1P24A+TDR+TXV+ furnace: A96UH1E070B12AHRI reference: 21032959016.008.0082002.08EPA 2458575
EA(C;U)1P24A+TDR+TXV+ furnace: A93UH1E045B12AHRI reference: 21032958816.008.0082002.06EPA 2458579