R5H5S31*K*AAA*
15 SEER2 HP
39 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for R5H5S31*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 39 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 39 / 39 |
| EER2 · BTU/Wh | 11.7–13 | 39 / 39 |
| HSPF2 · BTU/Wh | 7.8–8 | 39 / 39 |
| Cooling capacity · BTU/h | 27,400–29,400 | 39 / 39 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 29,400–30,600 | 39 / 39 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,500–18,200 | 39 / 39 |
| Heating capacity at 5°F / −15°C · BTU/h | 13,400–14,000 | 39 / 39 |
| COP at 5°F / −15°C | 2–2.06 | 39 / 39 |
| Equipment / loop type | HP - Split System | 39 / 39 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 39 / 39 |
| Compressor staging | Single stage | 39 / 39 |
| Connected capability | No | 39 / 39 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FHMA5*42L*C*AHRI reference: 217683367 | 16.00 | 8.00 | 13400 | 2.05 | EPA 4505989 → |
F5MA5*42L*C*AHRI reference: 217683368 | 16.00 | 8.00 | 13400 | 2.05 | EPA 4505990 → |
FMA5X30**AL*AHRI reference: 217683606 | 16.00 | 8.00 | 13700 | 2.00 | EPA 4506058 → |
FM(C,U)5Z36**AL*AHRI reference: 217683510 | 16.00 | 8.00 | 13400 | 2.00 | EPA 4506121 → |
FM(C,U)5Z30**AL*AHRI reference: 217683478 | 16.00 | 8.00 | 13400 | 2.00 | EPA 4506695 → |
FMA5X36**AL*AHRI reference: 217683638 | 16.00 | 8.00 | 13700 | 2.00 | EPA 4506743 → |
FHMA5*30L*B*AHRI reference: 217683239 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4506038 → |
F5MA5*30L*B*AHRI reference: 217683240 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4506039 → |
EA*5X37M21A*+ furnace: *97VTN1002122A*AHRI reference: 217691563 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506781 → |
EA*5X43M21A*+ furnace: *95MSU1002122A*AHRI reference: 217693089 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506801 → |
EA*5X37M21A*+ furnace: *92MSN0802120A*AHRI reference: 217690831 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506824 → |
EA*5X37M21A*+ furnace: *92MSN1002120A*AHRI reference: 217690854 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506847 → |
EA*5X37M21A*+ furnace: *80CSU0401712B*AHRI reference: 217689959 | 15.50 | 8.00 | 13900 | 2.06 | EPA 4506881 → |
EA*5X37M21A*+ furnace: *92MSN1002122A*AHRI reference: 217690876 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506900 → |
EA*5X37M21A*+ furnace: *80CSU0802120B*AHRI reference: 217690003 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506920 → |
EA*5X43M21A*+ furnace: *80CSU0401712B*AHRI reference: 217691806 | 15.50 | 8.00 | 13900 | 2.06 | EPA 4506938 → |
EA*5X43M21A*+ furnace: *97VTN1002122A*AHRI reference: 217693507 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506952 → |
EA*5X37M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 217690169 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4506975 → |
EA*5X37M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 217690194 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507000 → |
EA*5X43M21A*+ furnace: *80CSU0802120B*AHRI reference: 217691850 | 15.50 | 8.00 | 13900 | 2.04 | EPA 4507031 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.