Arcoaire / AIR-SOURCE HEAT PUMP

R5H5S24*K*AAA*

15 SEER2 HP · source records, page 5

187 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for R5H5S24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 187 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5187 / 187
EER2 · BTU/Wh11.7–13187 / 187
HSPF2 · BTU/Wh7.8–8.5187 / 187
Cooling capacity · BTU/h22,200–24,400187 / 187
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000187 / 187
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200187 / 187
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900187 / 187
COP at 5°F / −15°C1.96–2.26187 / 187
Equipment / loop typeHP - Split System187 / 187
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)187 / 187
Compressor stagingSingle stage187 / 187
Connected capabilityNo187 / 187

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M21A*+ furnace: *80VSL0902120B*AHRI reference: 21420171615.507.80116002.14EPA 3408413
EA*5X37M21A*+ furnace: *80MSU1002120A*AHRI reference: 21420174415.507.80116002.14EPA 3408440
EVD5X38M17A*+ furnace: *96VSN0601716B*AHRI reference: 21420761115.507.80114001.98EPA 3408492
EVD5X38M17A*+ furnace: *96VSN0801716B*AHRI reference: 21420763615.507.80113001.98EPA 3408508
EA*5X37M17A*+ furnace: *80MSU0401712A*AHRI reference: 21420008415.507.80113002.10EPA 3408521
EA*5X37M21A*+ furnace: *80CTL0702120B*AHRI reference: 21420190615.507.80116002.14EPA 3408576
EA*5X37M21A*+ furnace: *80CTL0701716B*AHRI reference: 21420187915.507.80115002.14EPA 3408590
EA*5X37M21A*+ furnace: *80CTL0901716B*AHRI reference: 21420193315.507.80115002.14EPA 3408604
EA*5X37M17A*+ furnace: *80CTL0701412B*AHRI reference: 21420016715.507.80112002.08EPA 3408638
EA*5X37M17A*+ furnace: *80CTL0701716B*AHRI reference: 21420019415.507.80113002.08EPA 3408664
EA*5X37M21A*+ furnace: *96VSN1002120B*AHRI reference: 21420275815.507.80116002.14EPA 3408724
EVM5X31M17A*+ furnace: *80MS(N,L)0701716A*AHRI reference: 21420349515.507.80113001.98EPA 3408749
EA*5X37M17A*+ furnace: *80CTL0901716B*AHRI reference: 21420022115.507.80113002.08EPA 3408767
EVD5X31M17A*+ furnace: *80VTL0701716B*AHRI reference: 21420518815.507.80113001.98EPA 3408786
EA*5X37M17A*+ furnace: *95MSU0601716A*AHRI reference: 21420102915.507.80113002.08EPA 3408809
EVD5X38M17A*+ furnace: *96VTN0601716B*AHRI reference: 21420775415.507.80114001.98EPA 3408891
EA*5X37M17A*+ furnace: *96CTN0601714B*AHRI reference: 21420111215.507.80114002.08EPA 3408952
EA*5X37M17A*+ furnace: *96CTN0801714B*AHRI reference: 21420113915.507.80113002.08EPA 3408979
EA*5X37M21A*+ furnace: *92MSN0801716A*AHRI reference: 21421178015.507.80114002.14EPA 3409193
EA*5X37M21A*+ furnace: *92MSN0802120A*AHRI reference: 21421181015.507.80115002.16EPA 3409223

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →