R5H5S19*K*AAA*
15 SEER2 HP · source records, page 2
77 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for R5H5S19*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 77 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 77 / 77 |
| EER2 · BTU/Wh | 12.5–13 | 77 / 77 |
| HSPF2 · BTU/Wh | 7.8–8 | 77 / 77 |
| Cooling capacity · BTU/h | 17,700–19,300 | 77 / 77 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 18,400–19,500 | 77 / 77 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 10,300–11,000 | 77 / 77 |
| Heating capacity at 5°F / −15°C · BTU/h | 7,900–8,500 | 77 / 77 |
| COP at 5°F / −15°C | 1.9–2 | 77 / 77 |
| Equipment / loop type | HP - Split System | 77 / 77 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 77 / 77 |
| Compressor staging | Single stage | 77 / 77 |
| Connected capability | No | 77 / 77 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X25M17A*+ furnace: *80MSU0601716A*AHRI reference: 217705185 | 16.00 | 8.00 | 8400 | 2.00 | EPA 4508245 → |
EA*5X25M17A*+ furnace: *80CTL0701412B*AHRI reference: 217705231 | 16.00 | 8.00 | 8400 | 2.00 | EPA 4508442 → |
EA*5X25M17A*+ furnace: *97CMN0801714B*AHRI reference: 217705403 | 16.00 | 8.00 | 8400 | 2.00 | EPA 4508525 → |
EA*5X25M17A*+ furnace: *80VTL0451412B*AHRI reference: 217705300 | 16.00 | 8.00 | 8400 | 2.00 | EPA 4508566 → |
EA*5X25M17A*+ furnace: *80VTL0701716B*AHRI reference: 217705332 | 16.00 | 8.00 | 8400 | 2.00 | EPA 4508598 → |
EA*5X19M17A*+ furnace: *96CTN0801714B*AHRI reference: 217702876 | 16.00 | 8.00 | 8300 | 2.00 | EPA 4508640 → |
EA*5X25M17A*+ furnace: *92MSN0801716A*AHRI reference: 217705505 | 16.00 | 8.00 | 8300 | 2.00 | EPA 4508753 → |
EA*5X25M17A*+ furnace: *92MSN0601412A*AHRI reference: 217705455 | 16.00 | 8.00 | 8300 | 2.00 | EPA 4508802 → |
EA*5X25M17A*+ furnace: *92MSN0601714A*AHRI reference: 217705478 | 16.00 | 8.00 | 8400 | 2.00 | EPA 4508826 → |
EA*5X19M17A*+ furnace: *80CSU0401712B*AHRI reference: 217702219 | 16.00 | 7.80 | 8300 | 1.95 | EPA 4508891 → |
FHMA5*24L*B*AHRI reference: 217686922 | 15.50 | 7.80 | 8000 | 1.90 | EPA 4505907 → |
F5MA5*24L*B*AHRI reference: 217686923 | 15.50 | 7.80 | 8000 | 1.90 | EPA 4505911 → |
FMA5X18**AL*AHRI reference: 217687193 | 15.50 | 7.80 | 7900 | 2.00 | EPA 4506313 → |
FMA5X24**AL*AHRI reference: 217687225 | 15.50 | 7.80 | 7900 | 2.00 | EPA 4506427 → |
FTMA5X24L0B*AHRI reference: 217687268 | 15.50 | 7.80 | 8100 | 1.95 | EPA 4506469 → |
FM(C,U)5Z18**AL*AHRI reference: 217687033 | 15.50 | 7.80 | 8100 | 2.00 | EPA 4506540 → |
FM(C,U)5Z24**AL*AHRI reference: 217687065 | 15.50 | 7.80 | 8100 | 2.00 | EPA 4506573 → |
EA*5X25M17A*+ furnace: *96MSN0801716A*AHRI reference: 217705634 | 15.50 | 8.00 | 8500 | 2.00 | EPA 4507394 → |
EA*5X25M17A*+ furnace: *96VSN0601412B*AHRI reference: 217705698 | 15.50 | 8.00 | 8400 | 2.00 | EPA 4507418 → |
EA*5X19M17A*+ furnace: *80VTL0701716B*AHRI reference: 217702316 | 15.50 | 8.00 | 8400 | 2.00 | EPA 4507448 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →