Arcoaire / AIR-SOURCE HEAT PUMP

Q5H9V60*K*AAA*

QuietComfort 19 SEER2 VS HP · source records, page 9

212 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.5BTU/Wh
HSPF2 range8–9BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for Q5H9V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 212 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.5212 / 212
EER2 · BTU/Wh10–12212 / 212
HSPF2 · BTU/Wh8–9212 / 212
Cooling capacity · BTU/h54,000–57,500212 / 212
Heating capacity at 47°F / 8.3°C · BTU/h56,500–62,000212 / 212
Heating capacity at 17°F / −8.3°C · BTU/h48,000–50,500212 / 212
Heating capacity at 5°F / −15°C · BTU/h39,000–42,000212 / 212
COP at 5°F / −15°C1.94–2.16212 / 212
Equipment / loop typeHP - Split System212 / 212
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)212 / 212
Compressor stagingContinuously variable212 / 212
Connected capabilityNo212 / 212

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVM5X60M21A*+ furnace: *96VTN0802120B*AHRI reference: 21791887215.508.00395001.96EPA 4541238
ESH5X60M12A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 21793303215.508.50405002.04EPA 4542416
EA*5X61M21A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 21793226615.508.50410002.00EPA 4542806
EA*5X60M24A*+ furnace: *97VTN1202422A*AHRI reference: 21793198115.509.00405002.14EPA 4543222
EA*5X60M24A*+ furnace: *97CTN1002122A*AHRI reference: 21793184615.509.00405002.12EPA 4543460
EA*5X61M21A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 21793210115.508.50410002.00EPA 4543520
EA*5X61M24A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 21793270215.508.50410002.05EPA 4543772
EA*5X60M24A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 21793189115.509.00405002.12EPA 4543975
EA*5X60M24A*+ furnace: *96VTN1202422B*AHRI reference: 21793192115.509.00405002.14EPA 4544002
EA*5X61M24A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 21793274715.508.50410002.00EPA 4544209
EA*5X61M24A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 21793276215.508.50410002.00EPA 4544222
EA*5X61M24A*+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 21793279215.508.50410002.05EPA 4544420
EA*5X61M24A*+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 21793283715.508.50410002.05EPA 4544465
EA*5X60M24A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 21793195115.509.00405002.12EPA 4544594
EA*5X61M21A*+ furnace: *80CSU0401712B*AHRI reference: 21793201115.508.50405002.00EPA 4544635
ESH5X60M12A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 21793307715.508.50405002.04EPA 4544947
EA*5X60M24A*+ furnace: *96CTN1002122B*AHRI reference: 21793180115.509.00405002.12EPA 4545018
EA*5X61M21A*+ furnace: *95CSU1002122B*AHRI reference: 21793217615.508.50405002.00EPA 4545049
EA*5X61M21A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 21793219115.508.50410002.00EPA 4545063
EA*5X61M21A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 21793222115.508.50410002.00EPA 4545345

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →