Arcoaire / AIR-SOURCE HEAT PUMP

Q5H9V60*K*AAA*

QuietComfort 19 SEER2 VS HP · source records, page 7

212 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.5BTU/Wh
HSPF2 range8–9BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for Q5H9V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 212 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.5212 / 212
EER2 · BTU/Wh10–12212 / 212
HSPF2 · BTU/Wh8–9212 / 212
Cooling capacity · BTU/h54,000–57,500212 / 212
Heating capacity at 47°F / 8.3°C · BTU/h56,500–62,000212 / 212
Heating capacity at 17°F / −8.3°C · BTU/h48,000–50,500212 / 212
Heating capacity at 5°F / −15°C · BTU/h39,000–42,000212 / 212
COP at 5°F / −15°C1.94–2.16212 / 212
Equipment / loop typeHP - Split System212 / 212
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)212 / 212
Compressor stagingContinuously variable212 / 212
Connected capabilityNo212 / 212

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVM5X60M21A*+ furnace: *97CMN0802120B*AHRI reference: 21791869215.508.00395001.96EPA 4537207
EVD5X60M21A*+ furnace: *95CSU1002122B*AHRI reference: 21792016815.508.00400001.94EPA 4537344
EVD5X60M21A*+ furnace: *80CSU0802120B*AHRI reference: 21791997315.508.00395001.96EPA 4537572
EVM5X61M24A*+ furnace: *80VSL1102122B*AHRI reference: 21791940015.508.00410001.96EPA 4537796
EVD5X61M21A*+ furnace: *96VSN0802120B*AHRI reference: 21792114615.508.00405001.96EPA 4538146
EVD5X61M21A*+ furnace: *96VSN1002120B*AHRI reference: 21792116115.508.00405001.96EPA 4538154
EVD5X60M21A*+ furnace: *96VSN1002120B*AHRI reference: 21792024315.508.00400001.96EPA 4538650
EVD5X60M21A*+ furnace: *95MSU1002122A*AHRI reference: 21792028815.508.00395001.96EPA 4538792
EVD5X60M21A*+ furnace: *97VTN1002120A*AHRI reference: 21792042415.508.00400001.96EPA 4538850
EVD5X60M21A*+ furnace: *96VTN0802120B*AHRI reference: 21792036315.508.00400001.94EPA 4538859
EVD5X61M21A*+ furnace: *97VTN1002120A*AHRI reference: 21792134215.508.00405001.96EPA 4538912
EVD5X61M21A*+ furnace: *97VTN0802120A*AHRI reference: 21792132715.508.00405001.96EPA 4538946
EVD5X61M24A*+ furnace: *80CTL1352422B*AHRI reference: 21792152215.508.00410001.96EPA 4538999
EVM5X61M24A*+ furnace: *80CTL0902120B*AHRI reference: 21791947515.508.00410001.96EPA 4539033
EVD5X60M21A*+ furnace: *96VTN1002120B*AHRI reference: 21792037915.508.00400001.96EPA 4539098
EVD5X60M21A*+ furnace: *97VTN0802120A*AHRI reference: 21792040915.508.00400001.94EPA 4539116
EVD5X61M21A*+ furnace: *96VTN1002120B*AHRI reference: 21792129715.508.00405001.96EPA 4539186
EVD5X61M24A*+ furnace: *80VTL1102122B*AHRI reference: 21792155215.508.00410001.96EPA 4539208
EVD5X61M24A*+ furnace: *80CSU0802120B*AHRI reference: 21792137215.508.00410001.96EPA 4539730
EVD5X60M21A*+ furnace: *80VSL0902120B*AHRI reference: 21792000315.508.00395001.94EPA 4539739

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →