Arcoaire / AIR-SOURCE HEAT PUMP

Q5H9V60*K*AAA*

QuietComfort 19 SEER2 VS HP · source records, page 3

212 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.5BTU/Wh
HSPF2 range8–9BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for Q5H9V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 212 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.5212 / 212
EER2 · BTU/Wh10–12212 / 212
HSPF2 · BTU/Wh8–9212 / 212
Cooling capacity · BTU/h54,000–57,500212 / 212
Heating capacity at 47°F / 8.3°C · BTU/h56,500–62,000212 / 212
Heating capacity at 17°F / −8.3°C · BTU/h48,000–50,500212 / 212
Heating capacity at 5°F / −15°C · BTU/h39,000–42,000212 / 212
COP at 5°F / −15°C1.94–2.16212 / 212
Equipment / loop typeHP - Split System212 / 212
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)212 / 212
Compressor stagingContinuously variable212 / 212
Connected capabilityNo212 / 212

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X61M21A*+ furnace: *97CTN1002122A*AHRI reference: 21792126616.008.00405001.96EPA 4540824
EVD5X61M21A*+ furnace: *80CTL0902120B*AHRI reference: 21792101116.008.00405001.96EPA 4541071
EVD5X61M21A*+ furnace: *80CTL1102120B*AHRI reference: 21792102616.008.00405001.96EPA 4541086
EVD5X61M21A*+ furnace: *80VTL0902120B*AHRI reference: 21792104116.008.00400001.96EPA 4541096
EVD5X60M21A*+ furnace: *80VTL1102122B*AHRI reference: 21792013816.008.00395001.96EPA 4541122
EVM5X60M21A*+ furnace: *80MSU0601716A*AHRI reference: 21791849716.008.00390001.94EPA 4541130
EVM5X60M21A*+ furnace: *80MSU0802120A*AHRI reference: 21791851216.008.00390001.94EPA 4541162
EVM5X60M21A*+ furnace: *80MSU1002120A*AHRI reference: 21791852716.008.00395001.94EPA 4541176
EVM5X60M21A*+ furnace: *97CTN1002122A*AHRI reference: 21791885716.008.00395001.94EPA 4541224
EA*5X61M24A*+ furnace: *80VSL1352422B*AHRI reference: 21793250616.009.00405002.12EPA 4541958
EA*5X61M24A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 21793253616.008.50410002.00EPA 4541996
EA*5X61M24A*+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 21793255116.008.50410002.00EPA 4542010
EA*5X61M21A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 21793228116.008.50410002.00EPA 4542802
EA*5X61M21A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 21793202616.008.50410002.05EPA 4543235
EA*5X61M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 21793204116.009.00410002.14EPA 4543248
EA*5X61M21A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 21793207116.008.50410002.00EPA 4543414
EA*5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 21793208616.008.50405002.00EPA 4543428
EA*5X60M24A*+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 21793186116.009.00405002.12EPA 4543475
EA*5X61M21A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 21793205616.009.00410002.12EPA 4543510
EA*5X60M24A*+ furnace: *80VSL1352422B*AHRI reference: 21793153016.009.00400002.12EPA 4543570

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →