Arcoaire / AIR-SOURCE HEAT PUMP

Q5H9V48*K*AAA*

QuietComfort 19 SEER2 VS HP · source records, page 20

507 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.5–10BTU/Wh
Cooling capacity43,500–49,500BTU/h

Each efficiency range summarizes published EPA records for Q5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19507 / 507
EER2 · BTU/Wh10–13.5507 / 507
HSPF2 · BTU/Wh8.5–10507 / 507
Cooling capacity · BTU/h43,500–49,500507 / 507
Heating capacity at 47°F / 8.3°C · BTU/h46,500–55,000507 / 507
Heating capacity at 17°F / −8.3°C · BTU/h38,500–47,000507 / 507
Heating capacity at 5°F / −15°C · BTU/h36,000–41,500507 / 507
COP at 5°F / −15°C1.95–2.32507 / 507
Equipment / loop typeHP - Split System507 / 507
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)507 / 507
Compressor stagingContinuously variable507 / 507
Connected capabilityNo507 / 507

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVM5X48M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 21795521915.509.00400002.10EPA 4565604 →
EVM5X48M21A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 21795522315.509.50400002.24EPA 4565608 →
EVM5X49M21A*+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 21795523915.509.00410002.10EPA 4565624 →
EVM5X49M21A*+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 21795524915.509.00410002.12EPA 4565634 →
EVD5X60M21A*+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 21795548515.509.00410002.10EPA 4565646 →
EVD5X60M21A*+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 21795549515.509.00405002.12EPA 4565655 →
EVD5X60M21A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 21795550915.509.00405002.12EPA 4565668 →
EVD5X60M21A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 21795551115.509.00405002.10EPA 4565670 →
EVD5X60M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 21795553115.509.50405002.24EPA 4565685 →
EVD5X60M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 21795552515.509.50405002.24EPA 4565720 →
EVM5X49M21A*+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 21795525115.509.00400002.15EPA 4565726 →
EVM5X49M21A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 21795526315.509.00405002.12EPA 4565736 →
EVM5X49M21A*+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 21795526915.509.00405002.12EPA 4565742 →
EVM5X49M21A*+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 21795527315.509.00405002.12EPA 4565746 →
EVM5X49M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 21795527915.509.00405002.15EPA 4565752 →
EVD5X49M24A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 21795546315.509.00410002.12EPA 4565756 →
EVD5X49M24A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 21795546515.509.00410002.12EPA 4565758 →
EVD5X60M21A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 21795546915.509.00400002.10EPA 4565762 →
EVM5X49M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 21795528515.509.00405002.15EPA 4565768 →
EVM5X60M21A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 21795528915.509.00400002.10EPA 4565772 →