Arcoaire / AIR-SOURCE HEAT PUMP

Q5H9V48*K*AAA*

QuietComfort 19 SEER2 VS HP · source records, page 17

507 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.5–10BTU/Wh
Cooling capacity43,500–49,500BTU/h

Each efficiency range summarizes published EPA records for Q5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19507 / 507
EER2 · BTU/Wh10–13.5507 / 507
HSPF2 · BTU/Wh8.5–10507 / 507
Cooling capacity · BTU/h43,500–49,500507 / 507
Heating capacity at 47°F / 8.3°C · BTU/h46,500–55,000507 / 507
Heating capacity at 17°F / −8.3°C · BTU/h38,500–47,000507 / 507
Heating capacity at 5°F / −15°C · BTU/h36,000–41,500507 / 507
COP at 5°F / −15°C1.95–2.32507 / 507
Equipment / loop typeHP - Split System507 / 507
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)507 / 507
Compressor stagingContinuously variable507 / 507
Connected capabilityNo507 / 507

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X60M24A*+ furnace: OMV154L20ACold climate designationAHRI reference: 21795585916.009.00376002.10EPA 4566199 →
ESH5X48M12A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 21795603715.508.50368002.00EPA 4565193 →
ESH5X48M12A*+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 21795605115.508.50366002.00EPA 4565203 →
ESH5X48M12A*+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 21795606115.508.50368002.00EPA 4565211 →
EA*5X60M24A*+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 21795580515.509.00374002.08EPA 4565216 →
ESH5X48M12A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 21795607715.508.50368002.00EPA 4565221 →
ESH5X48M12A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 21795608115.508.50368002.00EPA 4565225 →
ESH5X48M12A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 21795608315.508.50366002.00EPA 4565229 →
ESH5X48M12A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 21795608515.508.50366002.00EPA 4565231 →
ESH5X48M12A*+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 21795608915.508.50368002.00EPA 4565235 →
EVD5X48M21A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 21795536915.509.00400002.10EPA 4565244 →
EVD5X48M21A*+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 21795537315.509.00400002.10EPA 4565246 →
EVM5X48M21A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 21795519515.509.00400002.10EPA 4565253 →
EVD5X48M21A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 21795538115.509.50400002.24EPA 4565255 →
EVM5X48M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 21795519715.509.00400002.10EPA 4565258 →
EVD5X48M21A*+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 21795538515.509.00400002.10EPA 4565260 →
EVD5X48M21A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 21795538715.509.00405002.10EPA 4565262 →
EVD5X48M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 21795539315.509.00400002.10EPA 4565267 →
EVD5X48M21A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 21795539715.509.00400002.10EPA 4565270 →
EVD5X48M21A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 21795539915.509.00395002.10EPA 4565272 →