Q5H9V24*K*AAA*
QuietComfort 19 SEER2 VS HP · source records, page 17
1,093 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,093 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,093 / 1,093 |
| EER2 · BTU/Wh | 11.5–14 | 1,093 / 1,093 |
| HSPF2 · BTU/Wh | 8–10 | 1,093 / 1,093 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,093 / 1,093 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,093 / 1,093 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,093 / 1,093 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,093 / 1,093 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,093 / 1,093 |
| Equipment / loop type | HP - Split System | 1,093 / 1,093 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,093 / 1,093 |
| Compressor staging | Continuously variable | 1,093 / 1,093 |
| Connected capability | No | 1,093 / 1,093 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X32M17A*+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 217937767 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4556184 → |
EVM5X32M17A*+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 217937782 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4556199 → |
EVM5X32M17A*+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 217937797 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4556216 → |
EVD5X36M21A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 217942450 | 19.00 | 8.50 | 21200 | 1.88 | EPA 4556219 → |
EVD5X36M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 217942375 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4556230 → |
EVD5X31M17A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 217941189 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4556255 → |
EVD5X31M17A*+ furnace: *97CTN0601716A*Cold climate designationAHRI reference: 217941204 | 19.00 | 8.50 | 21800 | 1.92 | EPA 4556270 → |
EVD5X36M17A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217941402 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4556324 → |
EVD5X36M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 217941417 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4556339 → |
EVD5X36M17A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 217941432 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4556354 → |
EVD5X36M17A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217941447 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4556369 → |
EVM5X31M17A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 217937145 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4556381 → |
EVM5X31M17A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217937161 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4556397 → |
EVM5X31M17A*+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 217937177 | 19.00 | 8.50 | 21600 | 1.92 | EPA 4556413 → |
EVM5X31M17A*+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 217937192 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4556427 → |
EVD5X37M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217942948 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4556436 → |
EVD5X37M21A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 217942993 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4556457 → |
EVD5X37M21A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 217942963 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4556463 → |
EVM5X31M17A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 217937480 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4556492 → |
EVM5X31M17A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 217937495 | 19.00 | 8.50 | 21600 | 1.92 | EPA 4556507 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.