Arcoaire / AIR-SOURCE HEAT PUMP

N5H9V60*K*AAA*

Performance 19 SEER2 VS HP · source records, page 4

212 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.5BTU/Wh
HSPF2 range8–9BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for N5H9V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 212 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.5212 / 212
EER2 · BTU/Wh10–12212 / 212
HSPF2 · BTU/Wh8–9212 / 212
Cooling capacity · BTU/h54,000–57,500212 / 212
Heating capacity at 47°F / 8.3°C · BTU/h56,500–62,000212 / 212
Heating capacity at 17°F / −8.3°C · BTU/h48,000–50,500212 / 212
Heating capacity at 5°F / −15°C · BTU/h39,000–42,000212 / 212
COP at 5°F / −15°C1.94–2.16212 / 212
Equipment / loop typeHP - Split System212 / 212
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)212 / 212
Compressor stagingContinuously variable212 / 212
Connected capabilityNo212 / 212

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X60M24A*+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 21793185416.009.00405002.12EPA 4543468
EA*5X61M21A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 21793206416.008.50410002.00EPA 4543515
EA*5X61M21A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 21793210916.008.50410002.00EPA 4543529
EA*5X60M24A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 21793150816.009.00405002.12EPA 4543551
EA*5X60M24A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 21793146316.008.50405002.00EPA 4543557
EA*5X61M24A*+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 21793268016.008.50410002.00EPA 4543713
EA*5X61M24A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 21793271016.009.00410002.14EPA 4543780
EA*5X61M24A*+ furnace: *96VSN1202422B*AHRI reference: 21793272516.009.00405002.14EPA 4543794
EA*5X61M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 21793213916.009.00410002.14EPA 4543824
EA*5X61M21A*+ furnace: *80VTL1102122B*AHRI reference: 21793215416.009.00405002.14EPA 4543839
EA*5X61M21A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 21793212416.009.00410002.14EPA 4543912
EA*5X60M24A*+ furnace: *96VTN1002122B*AHRI reference: 21793189916.009.00400002.14EPA 4543983
EA*5X61M24A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 21793277016.008.50410002.05EPA 4544230
EA*5X61M24A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21793280016.009.00410002.14EPA 4544427
EA*5X61M24A*+ furnace: *96CTN1202422B*AHRI reference: 21793281516.009.00405002.14EPA 4544441
EA*5X60M24A*+ furnace: *80VSL1352422B*AHRI reference: 21793152316.009.00400002.12EPA 4544472
EA*5X60M24A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 21793153816.008.50405002.00EPA 4544491
EA*5X60M24A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 21793149316.009.00405002.12EPA 4544495
EA*5X60M24A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 21793162816.009.00405002.12EPA 4544506
EA*5X60M24A*+ furnace: *97VTN1002122A*AHRI reference: 21793195916.009.00400002.14EPA 4544602

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →