Arcoaire / AIR-SOURCE HEAT PUMP

N5H9V60*K*AAA*

Performance 19 SEER2 VS HP

212 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.5BTU/Wh
HSPF2 range8–9BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for N5H9V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 212 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.5212 / 212
EER2 · BTU/Wh10–12212 / 212
HSPF2 · BTU/Wh8–9212 / 212
Cooling capacity · BTU/h54,000–57,500212 / 212
Heating capacity at 47°F / 8.3°C · BTU/h56,500–62,000212 / 212
Heating capacity at 17°F / −8.3°C · BTU/h48,000–50,500212 / 212
Heating capacity at 5°F / −15°C · BTU/h39,000–42,000212 / 212
COP at 5°F / −15°C1.94–2.16212 / 212
Equipment / loop typeHP - Split System212 / 212
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)212 / 212
Compressor stagingContinuously variable212 / 212
Connected capabilityNo212 / 212

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
QFVA5D6021X*Cold climate designationAHRI reference: 21869557517.508.10400002.00EPA 4683252 →
FTMA5B60L0D*Cold climate designationAHRI reference: 21791838517.009.00410002.12EPA 4538451 →
EA*5X61M24A*+ furnace: *80MSU0802120A*AHRI reference: 21793251416.508.50405002.05EPA 4541974 →
EA*5X61M24A*+ furnace: *80CSU0802120B*AHRI reference: 21793243916.508.50405002.05EPA 4547274 →
EVM5X60M21A*+ furnace: *80VTL1102122B*AHRI reference: 21791862516.008.00390001.96EPA 4536526 →
EVM5X60M21A*+ furnace: *95CSU1002122B*AHRI reference: 21791865516.008.00390001.96EPA 4536540 →
EVM5X61M24A*+ furnace: *97VTN1002122A*AHRI reference: 21791989116.008.00405001.96EPA 4536583 →
EVD5X61M21A*+ furnace: *80VTL1102122B*AHRI reference: 21792104916.008.00405001.96EPA 4536646 →
EVD5X61M21A*+ furnace: *97CMN1002122B*AHRI reference: 21792112416.008.00405001.96EPA 4536678 →
EVM5X61M24A*+ furnace: *96VTN1002122B*AHRI reference: 21791983016.008.00405001.96EPA 4536700 →
EVM5X60M21A*+ furnace: *96VTN1002122B*AHRI reference: 21791889616.008.00395001.96EPA 4536984 →
EVM5X60M21A*+ furnace: *97VTN1002120A*AHRI reference: 21791892616.008.00395001.94EPA 4537013 →
EVM5X60M21A*+ furnace: *97VTN1002122A*AHRI reference: 21791894116.008.00395001.96EPA 4537028 →
EVM5X60M21A*+ furnace: *80CTL0902120B*AHRI reference: 21791856516.008.00395001.94EPA 4537064 →
EVM5X60M21A*+ furnace: *80CTL1102120B*AHRI reference: 21791858016.008.00395001.94EPA 4537077 →
EVM5X60M21A*+ furnace: *97CMN1002122B*AHRI reference: 21791870016.008.00395001.94EPA 4537217 →
EVD5X61M21A*+ furnace: *95MSU1002122A*AHRI reference: 21792119916.008.00405001.96EPA 4537349 →
EVD5X61M21A*+ furnace: *96CTN1002122B*AHRI reference: 21792122916.008.00405001.96EPA 4537362 →
EVM5X61M24A*+ furnace: *80VSL1352422B*AHRI reference: 21791940816.008.00410001.96EPA 4537803 →
EVM5X61M24A*+ furnace: *80MSU0802120A*AHRI reference: 21791942316.008.00410001.96EPA 4537821 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →