N5H9V48*K*AAA*
Performance 19 SEER2 VS HP · source records, page 17
507 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
ESH5X48M12A*+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 217953002 | 16.00 | 8.50 | 36800 | 2.00 | EPA 4563655 → |
EVM5X60M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 217916190 | 15.50 | 9.50 | 40500 | 2.24 | EPA 4529824 → |
EVM5X49M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 217915721 | 15.50 | 9.00 | 40500 | 2.15 | EPA 4529967 → |
EVM5X48M21A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 217915043 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4530387 → |
EVM5X48M21A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 217915147 | 15.50 | 9.00 | 40500 | 2.10 | EPA 4530413 → |
EVM5X48M21A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 217915173 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4530441 → |
EVM5X48M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 217915186 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4530454 → |
EVM5X48M21A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 217915082 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4530474 → |
EVM5X49M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 217915760 | 15.50 | 9.00 | 40500 | 2.15 | EPA 4530747 → |
EVD5X48M21A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 217916216 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4530861 → |
EVD5X48M21A*+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 217916229 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4530927 → |
EVD5X48M21A*+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 217916255 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4530954 → |
EVM5X48M21A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 217915212 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4531001 → |
EVM5X60M21A*+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 217915890 | 15.50 | 9.00 | 41000 | 2.10 | EPA 4531934 → |
EVM5X48M21A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 217915317 | 15.50 | 9.50 | 40000 | 2.24 | EPA 4532091 → |
EVM5X48M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 217915330 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4532117 → |
EVM5X48M21A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 217915356 | 15.50 | 9.50 | 40000 | 2.24 | EPA 4532455 → |
EVD5X49M24A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 217916724 | 15.50 | 9.00 | 40500 | 2.15 | EPA 4532730 → |
EVD5X49M24A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 217916751 | 15.50 | 9.00 | 41000 | 2.12 | EPA 4532758 → |
EVD5X49M24A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 217916764 | 15.50 | 9.00 | 40500 | 2.12 | EPA 4532773 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →