Arcoaire / AIR-SOURCE HEAT PUMP

N5H9V48*K*AAA*

Performance 19 SEER2 VS HP

507 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.5–10BTU/Wh
Cooling capacity43,500–49,500BTU/h

Each efficiency range summarizes published EPA records for N5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19507 / 507
EER2 · BTU/Wh10–13.5507 / 507
HSPF2 · BTU/Wh8.5–10507 / 507
Cooling capacity · BTU/h43,500–49,500507 / 507
Heating capacity at 47°F / 8.3°C · BTU/h46,500–55,000507 / 507
Heating capacity at 17°F / −8.3°C · BTU/h38,500–47,000507 / 507
Heating capacity at 5°F / −15°C · BTU/h36,000–41,500507 / 507
COP at 5°F / −15°C1.95–2.32507 / 507
Equipment / loop typeHP - Split System507 / 507
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)507 / 507
Compressor stagingContinuously variable507 / 507
Connected capabilityNo507 / 507

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FTMA5B60L0D*Cold climate designationAHRI reference: 21791493919.0010.00360002.32EPA 4533126 →
QFVA5D6021X*Cold climate designationAHRI reference: 21869555919.0010.00385002.12EPA 4683268 →
QFVA5D4821X*Cold climate designationAHRI reference: 21869554319.009.50385002.12EPA 4683284 →
FTMA5B48L0C*Cold climate designationAHRI reference: 21791492318.009.00364002.10EPA 4533109 →
EA*5X61M21A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 21792953617.509.00368002.10EPA 4545002 →
EVM5X60M21A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 21791616417.009.50400002.24EPA 4534308 →
EVM5X60M21A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 21791620317.009.50400002.24EPA 4534334 →
EVD5X60M21A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 21791732517.009.50400002.24EPA 4538489 →
EVD5X60M21A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 21791737217.009.50400002.24EPA 4538529 →
EVD5X61M21A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 21791738517.009.00405002.10EPA 4539433 →
EVD5X61M21A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 21791748917.009.50405002.24EPA 4539502 →
EVD5X61M21A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 21791750217.009.50405002.24EPA 4539875 →
EVD5X61M24A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 21791782817.009.50405002.22EPA 4540222 →
EVD5X61M21A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 21791745017.009.50400002.24EPA 4540584 →
EA*5X61M21A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 21792945817.009.00366002.10EPA 4542080 →
EA*5X61M21A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 21792957517.009.00368002.10EPA 4542701 →
EA*5X61M21A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 21792958817.009.00370002.10EPA 4542714 →
EA*5X61M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 21792961417.009.00370002.10EPA 4542841 →
EA*5X61M21A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 21792973117.009.00370002.10EPA 4543294 →
EA*5X61M21A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21792975717.009.00372002.10EPA 4543319 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →