Arcoaire / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 7

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11.7–13.5407 / 407
HSPF2 · BTU/Wh7.8–8.5407 / 407
Cooling capacity · BTU/h45,500–50,500407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600407 / 407
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600407 / 407
COP at 5°F / −15°C2.06–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X61M24A*+ furnace: *97VTN0802120A*AHRI reference: 21572249017.008.00256002.10EPA 3982702
EVD5X61M24A*+ furnace: *97VTN1002120A*AHRI reference: 21572250617.008.00252002.12EPA 3982720
EVM5X48M21A*+ furnace: *80VSL0902120B*AHRI reference: 21562291316.508.10244002.12EPA 3947318
EVM5X48M21A*+ furnace: *80VSL1102122B*AHRI reference: 21562292616.508.10244002.14EPA 3947331
EVM5X48M21A*+ furnace: *80MSU0601716A*AHRI reference: 21562294216.508.10246002.12EPA 3947346
EVM5X48M21A*+ furnace: *80MSU1002120A*AHRI reference: 21562298016.508.10246002.12EPA 3947382
EVM5X48M21A*+ furnace: *80CTL0902120B*AHRI reference: 21562301016.508.10244002.14EPA 3947414
EVM5X48M21A*+ furnace: *80CTL1102120B*AHRI reference: 21562302416.508.10244002.12EPA 3947427
EVM5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 21562304116.508.10244002.12EPA 3947443
EVM5X48M21A*+ furnace: *80VTL1102122B*AHRI reference: 21562305716.508.10244002.14EPA 3947461
EVM5X48M21A*+ furnace: *95MSU1002120A*AHRI reference: 21562316316.508.10244002.12EPA 3947508
EVM5X48M21A*+ furnace: *95MSU1002122A*AHRI reference: 21562317916.508.10246002.12EPA 3947523
EVM5X48M21A*+ furnace: *96VTN1002122B*AHRI reference: 21562325716.508.10242002.12EPA 3947582
EVM5X49M21A*+ furnace: *80CTL0702120B*AHRI reference: 21562335316.508.10256002.08EPA 3947677
EVM5X49M21A*+ furnace: *95CSU0802120B*AHRI reference: 21562342916.508.10252002.10EPA 3947756
EVM5X49M21A*+ furnace: *95CSU1002122B*AHRI reference: 21562344316.508.10246002.14EPA 3947769
EVM5X49M21A*+ furnace: *97CMN0802120B*AHRI reference: 21562347116.508.10252002.08EPA 3947781
EVM5X49M21A*+ furnace: *96VSN0802120B*AHRI reference: 21562349916.508.10250002.12EPA 3947807
EVM5X49M21A*+ furnace: *96VSN1002120B*AHRI reference: 21562351216.508.10250002.10EPA 3947821
EVM5X49M21A*+ furnace: *95MSU0802120A*AHRI reference: 21562352816.508.10250002.12EPA 3947837

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →