Arcoaire / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 17

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11.7–13.5407 / 407
HSPF2 · BTU/Wh7.8–8.5407 / 407
Cooling capacity · BTU/h45,500–50,500407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600407 / 407
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600407 / 407
COP at 5°F / −15°C2.06–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X60M12A*+ furnace: *96VTN0802120B*AHRI reference: 21563462716.008.00252002.20EPA 3953985 →
ESH5X60M12A*+ furnace: *80VSL1102122B*AHRI reference: 21563406916.008.00250002.25EPA 3953990 →
ESH5X60M12A*+ furnace: *80VSL1352422B*AHRI reference: 21563408216.008.00250002.25EPA 3954004 →
ESH5X60M12A*+ furnace: *80MSU0601716A*AHRI reference: 21563409816.007.80252002.20EPA 3954018 →
ESH5X60M12A*+ furnace: *96VTN1002120B*AHRI reference: 21563464516.008.00252002.25EPA 3954048 →
ESH5X60M12A*+ furnace: *96VTN1002122B*AHRI reference: 21563466016.008.00250002.25EPA 3954063 →
ESH5X60M12A*+ furnace: *96VTN1202422B*AHRI reference: 21563467816.008.00252002.25EPA 3954082 →
ESH5X60M12A*+ furnace: *80MSU0802120A*AHRI reference: 21563411716.008.00248002.25EPA 3954107 →
ESH5X60M12A*+ furnace: *80CTL0702120B*AHRI reference: 21563418016.008.00254002.20EPA 3954143 →
ESH5X60M12A*+ furnace: *80CTL0902120B*AHRI reference: 21563419416.008.00252002.25EPA 3954155 →
ESH5X60M12A*+ furnace: *80CTL1102120B*AHRI reference: 21563420816.008.00252002.25EPA 3954167 →
ESH5X60M12A*+ furnace: *80CTL1352422B*AHRI reference: 21563422216.008.00250002.25EPA 3954181 →
ESH5X60M12A*+ furnace: *80VTL0902120B*AHRI reference: 21563425516.008.00250002.25EPA 3954199 →
ESH5X60M12A*+ furnace: *80VTL1102122B*AHRI reference: 21563427116.008.00250002.25EPA 3954215 →
ESH5X60M12A*+ furnace: *97CMN1202422B*AHRI reference: 21563439216.008.00254002.20EPA 3954252 →
ESH5X60M12A*+ furnace: *96VSN0802120B*AHRI reference: 21563443216.008.00252002.20EPA 3954266 →
ESH5X60M12A*+ furnace: *96VSN1002120B*AHRI reference: 21563444516.008.00252002.20EPA 3954281 →
ESH5X60M12A*+ furnace: *96VSN1202422B*AHRI reference: 21563445816.008.00252002.25EPA 3954291 →
EA*5X60M24A*+ furnace: *97VTN1002122A*AHRI reference: 21572176316.008.00254002.22EPA 3981815 →
EA*5X61M21A*+ furnace: *80CSU0802120B*AHRI reference: 21572177616.008.00252002.26EPA 3981821 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →