Arcoaire / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 14

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11.7–13.5407 / 407
HSPF2 · BTU/Wh7.8–8.5407 / 407
Cooling capacity · BTU/h45,500–50,500407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600407 / 407
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600407 / 407
COP at 5°F / −15°C2.06–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X48M21A*+ furnace: *80VTL1102122B*AHRI reference: 21563143916.008.10250002.22EPA 3952340
EA*5X48M21A*+ furnace: *95CSU1002122B*AHRI reference: 21563148216.008.10250002.22EPA 3952367
EA*5X48M21A*+ furnace: *95MSU1002120A*AHRI reference: 21563164516.008.10252002.20EPA 3952446
EA*5X48M21A*+ furnace: *95MSU1002122A*AHRI reference: 21563166116.008.10248002.22EPA 3952458
EA*5X48M21A*+ furnace: *96CTN0802120B*AHRI reference: 21563167516.008.10250002.22EPA 3952474
EA*5X48M21A*+ furnace: *96VTN1002122B*AHRI reference: 21563177916.008.10248002.24EPA 3952521
EA*5X60M24A*+ furnace: *80VSL0902120B*AHRI reference: 21563182016.008.10258002.18EPA 3952536
EA*5X60M24A*+ furnace: *80VSL1102122B*AHRI reference: 21563183316.008.10256002.20EPA 3952550
EA*5X60M24A*+ furnace: *80VSL1352422B*AHRI reference: 21563184616.008.10258002.18EPA 3952563
EA*5X60M24A*+ furnace: *80VTL0902120B*AHRI reference: 21563195616.008.10258002.18EPA 3952593
EA*5X60M24A*+ furnace: *80VTL1102122B*AHRI reference: 21563197216.008.10256002.20EPA 3952604
EA*5X60M24A*+ furnace: *95CSU1002122B*AHRI reference: 21563200916.008.10256002.20EPA 3952625
EA*5X61M21A*+ furnace: *80CTL0702120B*AHRI reference: 21563245916.008.10262002.18EPA 3952754
EA*5X60M24A*+ furnace: *95MSU1002122A*AHRI reference: 21563215616.008.10256002.22EPA 3952819
EA*5X60M24A*+ furnace: *96CTN0802120B*AHRI reference: 21563217016.008.10260002.18EPA 3952833
EA*5X60M24A*+ furnace: *96VTN1002122B*AHRI reference: 21563224816.008.10254002.22EPA 3952911
EA*5X61M21A*+ furnace: *97CMN0802120B*AHRI reference: 21563259316.008.10258002.20EPA 3952949
EA*5X61M21A*+ furnace: *96VSN0802120B*AHRI reference: 21563262116.008.10256002.20EPA 3952975
EA*5X61M21A*+ furnace: *80CSU0802120A*AHRI reference: 21563230716.008.10254002.22EPA 3952994
EA*5X61M21A*+ furnace: *80VTL1102122B*AHRI reference: 21563253616.008.10254002.22EPA 3953124

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →