Arcoaire / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11.7–13.5407 / 407
HSPF2 · BTU/Wh7.8–8.5407 / 407
Cooling capacity · BTU/h45,500–50,500407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600407 / 407
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600407 / 407
COP at 5°F / −15°C2.06–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FTMA5B60L0D*AHRI reference: 21556072118.008.10246002.32EPA 3982805
QFVA5D6021X*AHRI reference: 21869544818.008.50258002.32EPA 4683379
EVM5X49M21A*+ furnace: *80MSU0802120A*AHRI reference: 21562331817.508.10244002.14EPA 3947642
EVM5X60M21A*+ furnace: *96VTN1002122B*AHRI reference: 21562403917.508.10244002.14EPA 3948045
EVM5X60M21A*+ furnace: *80MSU0802120A*AHRI reference: 21562371617.508.10244002.14EPA 3948279
EVD5X49M24A*+ furnace: *80MSU0802120A*AHRI reference: 21562447417.508.10246002.14EPA 3948717
EVD5X60M21A*+ furnace: *96VTN1002122B*AHRI reference: 21562500417.508.10244002.14EPA 3949145
EVD5X61M21A*+ furnace: *80VSL1102122B*AHRI reference: 21562503017.508.50248002.26EPA 3949240
EVD5X61M21A*+ furnace: *80MSU0601716A*AHRI reference: 21562504617.508.10250002.12EPA 3949257
EVD5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 21562506517.508.50244002.30EPA 3949277
EVD5X61M21A*+ furnace: *80MSU1002120A*AHRI reference: 21562508417.508.50250002.26EPA 3949299
EVD5X61M21A*+ furnace: *80CTL0902120B*AHRI reference: 21562511417.508.50252002.24EPA 3949324
EVD5X61M21A*+ furnace: *80CTL1102120B*AHRI reference: 21562512817.508.50250002.24EPA 3949338
EVD5X61M24A*+ furnace: *80VSL1352422B*AHRI reference: 21562541317.508.50252002.24EPA 3949360
EVD5X61M24A*+ furnace: *95MSU1002122A*AHRI reference: 21562566217.508.50250002.26EPA 3949438
EVD5X61M21A*+ furnace: *80VTL1102122B*AHRI reference: 21562516117.508.10246002.14EPA 3949462
EVD5X61M21A*+ furnace: *95MSU1002122A*AHRI reference: 21562529617.508.10244002.16EPA 3949596
EVD5X61M21A*+ furnace: *96VTN1002122B*AHRI reference: 21562537417.508.50246002.28EPA 3949746
EVD5X61M24A*+ furnace: *80VSL1102122B*AHRI reference: 21562540017.508.50250002.24EPA 3949771
EVD5X61M24A*+ furnace: *80CTL1352422B*AHRI reference: 21562547317.508.50248002.28EPA 3949809

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →