Arcoaire / AIR-SOURCE HEAT PUMP

N5H8T36*K*AAA*

2-STAGE 18 SEER HP · source records, page 5

257 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17257 / 257
EER2 · BTU/Wh11.7–13257 / 257
HSPF2 · BTU/Wh7.8–8.5257 / 257
Cooling capacity · BTU/h33,800–38,000257 / 257
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000257 / 257
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200257 / 257
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600257 / 257
COP at 5°F / −15°C1.78–2.48257 / 257
Equipment / loop typeHP - Split System257 / 257
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)257 / 257
Compressor stagingTwo-stage257 / 257
Connected capabilityNo257 / 257

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M21A*+ furnace: *80CTL1102120B*AHRI reference: 21563584015.508.10193002.24EPA 3954726
EA*5X37M21A*+ furnace: *80VTL0902120B*AHRI reference: 21563588115.508.10193002.26EPA 3954767
EA*5X37M21A*+ furnace: *80VTL1102122B*AHRI reference: 21563589715.508.10195002.24EPA 3954779
EA*5X37M17A*+ furnace: *80MSU0401712A*AHRI reference: 21563521815.508.10188002.26EPA 3954790
EA*5X37M17A*+ furnace: *80MSU0601716A*AHRI reference: 21563523715.508.10188002.28EPA 3954814
EA*5X37M21A*+ furnace: *97CMN1002122B*AHRI reference: 21563600815.508.10193002.24EPA 3954941
EA*5X37M21A*+ furnace: *96VSN0802120B*AHRI reference: 21563604815.508.10193002.26EPA 3954954
EA*5X37M21A*+ furnace: *95CSU0802120B*AHRI reference: 21563592415.508.10193002.24EPA 3954963
EA*5X37M21A*+ furnace: *95CSU1002122B*AHRI reference: 21563593815.508.10193002.24EPA 3954980
EA*5X37M21A*+ furnace: *96VSN1002120B*AHRI reference: 21563606115.508.10194002.26EPA 3954998
EA*5X37M21A*+ furnace: *97CMN0802120B*AHRI reference: 21563599415.508.10193002.26EPA 3955002
EA*5X37M21A*+ furnace: *95MSU0802120A*AHRI reference: 21563610115.508.10193002.26EPA 3955033
EA*5X37M21A*+ furnace: *95MSU1002120A*AHRI reference: 21563612515.508.10194002.24EPA 3955050
EA*5X37M21A*+ furnace: *96CTN1002122B*AHRI reference: 21563623915.508.10193002.24EPA 3955092
EA*5X37M21A*+ furnace: *96VTN0802120B*AHRI reference: 21563632815.508.10193002.26EPA 3955110
EA*5X37M21A*+ furnace: *96VTN1002120B*AHRI reference: 21563635815.508.10193002.26EPA 3955126
EA*5X42M21A*+ furnace: *80MSU0802120A*AHRI reference: 21563665315.508.10188002.24EPA 3955189
EA*5X42M21A*+ furnace: *80VTL0902120B*AHRI reference: 21563687315.508.10189002.24EPA 3955285
EA*5X42M21A*+ furnace: *96VTN1002122B*AHRI reference: 21563756615.508.10188002.26EPA 3955419
EA*5X43M21A*+ furnace: *80VSL0701716B*AHRI reference: 21563766315.508.10194002.24EPA 3955459

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →