Arcoaire / AIR-SOURCE HEAT PUMP

N5H8T36*K*AAA*

2-STAGE 18 SEER HP · source records, page 12

257 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17257 / 257
EER2 · BTU/Wh11.7–13257 / 257
HSPF2 · BTU/Wh7.8–8.5257 / 257
Cooling capacity · BTU/h33,800–38,000257 / 257
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000257 / 257
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200257 / 257
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600257 / 257
COP at 5°F / −15°C1.78–2.48257 / 257
Equipment / loop typeHP - Split System257 / 257
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)257 / 257
Compressor stagingTwo-stage257 / 257
Connected capabilityNo257 / 257

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X48M21A*+ furnace: *80VTL0701716B*AHRI reference: 21563907415.208.10193002.24EPA 3956245 →
EA*5X48M21A*+ furnace: *95CSU0802120B*AHRI reference: 21563918315.208.10192002.26EPA 3956294 →
EA*5X48M21A*+ furnace: *96VSN0802120B*AHRI reference: 21563938215.208.10192002.24EPA 3956350 →
EA*5X48M21A*+ furnace: *95MSU0802120A*AHRI reference: 21563948315.208.10192002.24EPA 3956379 →
EA*5X48M21A*+ furnace: *96VTN0802120B*AHRI reference: 21563970715.208.10192002.24EPA 3956412 →
ESH5X36M12A*+ furnace: *80MSU0802120A*AHRI reference: 21564001915.207.80188002.26EPA 3956508 →
ESH5X36M12A*+ furnace: *96VTN1002122B*AHRI reference: 21564068115.207.80190002.24EPA 3956523 →
ESH5X42M12A*+ furnace: *80CSU0802120A*AHRI reference: 21564079115.208.10192002.24EPA 3956544 →
ESH5X42M12A*+ furnace: *80VSL0902120B*AHRI reference: 21564089815.207.80191002.26EPA 3956555 →
ESH5X48M12A*+ furnace: *80CTL1102120B*AHRI reference: 21564236415.208.10191002.26EPA 3956570 →
ESH5X48M12A*+ furnace: *80CTL1352422B*AHRI reference: 21564238615.208.10190002.26EPA 3956595 →
ESH5X48M12A*+ furnace: *80VTL0902120B*AHRI reference: 21564244415.208.10192002.24EPA 3956610 →
ESH5X48M12A*+ furnace: *95CSU1002122B*AHRI reference: 21564249715.208.10190002.26EPA 3956628 →
ESH5X48M12A*+ furnace: *97CMN1002122B*AHRI reference: 21564255315.208.10191002.26EPA 3956645 →
ESH5X48M12A*+ furnace: *96VSN1202422B*AHRI reference: 21564264815.207.80190002.26EPA 3956659 →
ESH5X48M12A*+ furnace: *95MSU0802120A*AHRI reference: 21564270315.207.80192002.26EPA 3956668 →
ESH5X48M12A*+ furnace: *95MSU1002122A*AHRI reference: 21564275415.208.10190002.26EPA 3956684 →
ESH5X42M12A*+ furnace: *80VSL1102122B*AHRI reference: 21564091715.207.80190002.26EPA 3956700 →
ESH5X42M12A*+ furnace: *80MSU0601716A*AHRI reference: 21564099115.207.80190002.26EPA 3956718 →
ESH5X42M12A*+ furnace: *80VTL0902120B*AHRI reference: 21564131215.207.80191002.26EPA 3956755 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.