Arcoaire / AIR-SOURCE HEAT PUMP

N5H8T36*K*AAA*

2-STAGE 18 SEER HP · source records, page 10

257 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17257 / 257
EER2 · BTU/Wh11.7–13257 / 257
HSPF2 · BTU/Wh7.8–8.5257 / 257
Cooling capacity · BTU/h33,800–38,000257 / 257
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000257 / 257
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200257 / 257
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600257 / 257
COP at 5°F / −15°C1.78–2.48257 / 257
Equipment / loop typeHP - Split System257 / 257
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)257 / 257
Compressor stagingTwo-stage257 / 257
Connected capabilityNo257 / 257

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M21A*+ furnace: *80VTL0701716B*AHRI reference: 21563585715.208.10194002.26EPA 3954734
EA*5X37M17A*+ furnace: *80CTL0701412B*AHRI reference: 21563526715.208.10190002.26EPA 3954831
EA*5X37M17A*+ furnace: *80CTL0701716B*AHRI reference: 21563528115.208.10190002.26EPA 3954840
EA*5X37M17A*+ furnace: *80CTL0901716B*AHRI reference: 21563529515.208.10189002.26EPA 3954857
EA*5X37M17A*+ furnace: *80VTL0451412B*AHRI reference: 21563531215.208.10189002.26EPA 3954874
EA*5X37M17A*+ furnace: *80VTL0701716B*AHRI reference: 21563534015.208.10189002.26EPA 3954898
EA*5X37M17A*+ furnace: *95CSU0601716B*AHRI reference: 21563536315.208.10189002.26EPA 3954919
EA*5X37M21A*+ furnace: *95MSU0601716A*AHRI reference: 21563607815.208.10196002.24EPA 3955015
EA*5X37M21A*+ furnace: *96CTN0801714B*AHRI reference: 21563619315.208.10196002.24EPA 3955078
EA*5X42M21A*+ furnace: *80VSL0901716B*AHRI reference: 21563651515.208.10188002.22EPA 3955153
EA*5X42M21A*+ furnace: *80MSU0601716A*AHRI reference: 21563662015.208.10188002.24EPA 3955170
EA*5X42M21A*+ furnace: *80CTL0901716B*AHRI reference: 21563676015.208.10189002.22EPA 3955206
EA*5X42M21A*+ furnace: *80VSL0902120B*AHRI reference: 21563653615.208.10189002.24EPA 3955222
EA*5X42M21A*+ furnace: *80VSL1102122B*AHRI reference: 21563655815.208.10188002.24EPA 3955233
EA*5X42M21A*+ furnace: *80CTL0902120B*AHRI reference: 21563678515.208.10189002.24EPA 3955245
EA*5X42M21A*+ furnace: *80CTL1102120B*AHRI reference: 21563680615.208.10188002.24EPA 3955259
EA*5X42M21A*+ furnace: *80VTL1102122B*AHRI reference: 21563689815.208.10188002.24EPA 3955301
EA*5X42M21A*+ furnace: *95CSU1002122B*AHRI reference: 21563698115.208.10189002.24EPA 3955316
EA*5X42M21A*+ furnace: *97CMN0802120B*AHRI reference: 21563708615.208.10188002.22EPA 3955330
EA*5X42M21A*+ furnace: *97CMN1002122B*AHRI reference: 21563711615.208.10188002.24EPA 3955344

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →