Arcoaire / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 4

514 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5514 / 514
EER2 · BTU/Wh11.5–14514 / 514
HSPF2 · BTU/Wh7.8–8.5514 / 514
Cooling capacity · BTU/h22,200–25,000514 / 514
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400514 / 514
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000514 / 514
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500514 / 514
COP at 5°F / −15°C1.9–2.24514 / 514
Equipment / loop typeHP - Split System514 / 514
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)514 / 514
Compressor stagingTwo-stage514 / 514
Connected capabilityNo514 / 514

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M21A*+ furnace: *96CTN0802120B*AHRI reference: 21564858317.508.00112002.10EPA 3719648 →
EVM5X31M17A*+ furnace: *80VSL0451412B*AHRI reference: 21561383017.507.80109001.98EPA 3945995 →
EA*5X25M17A*+ furnace: *80VSL0451412B*AHRI reference: 21564438917.508.10110002.10EPA 3957784 →
EA*5X25M17A*+ furnace: *80VSL0901716B*AHRI reference: 21564444817.508.10111002.10EPA 3957822 →
EA*5X25M17A*+ furnace: *80MSU0601716A*AHRI reference: 21564450017.508.10110002.10EPA 3957856 →
EA*5X25M17A*+ furnace: *80CTL0701716B*AHRI reference: 21564456517.508.10111002.10EPA 3957904 →
EA*5X25M17A*+ furnace: *80CTL0901716B*AHRI reference: 21564458517.508.10111002.10EPA 3957920 →
EA*5X25M17A*+ furnace: *80VTL0451412B*AHRI reference: 21564461017.508.10110002.10EPA 3957933 →
EA*5X25M17A*+ furnace: *80VTL0701716B*AHRI reference: 21564465417.508.10111002.10EPA 3957962 →
EA*5X25M17A*+ furnace: *95CSU0601716B*AHRI reference: 21564469017.508.10111002.10EPA 3957985 →
EA*5X25M17A*+ furnace: *97CMN0601714B*AHRI reference: 21564471117.508.10111002.08EPA 3958001 →
EA*5X25M17A*+ furnace: *97CMN0801714B*AHRI reference: 21564473117.508.10111002.08EPA 3958013 →
EA*5X25M17A*+ furnace: *96VTN0801716B*AHRI reference: 21564508517.508.10111002.08EPA 3958048 →
EA*5X25M17A*+ furnace: *96VSN0601716B*AHRI reference: 21564481117.508.10112002.08EPA 3958081 →
EA*5X25M17A*+ furnace: *96VSN0801716B*AHRI reference: 21564483017.508.10111002.08EPA 3958093 →
EA*5X25M17A*+ furnace: *95MSU0601716A*AHRI reference: 21564488117.508.10111002.10EPA 3958126 →
EA*5X25M17A*+ furnace: *96CTN0601714B*AHRI reference: 21564492817.508.10111002.08EPA 3958156 →
EA*5X25M17A*+ furnace: *96CTN0801714B*AHRI reference: 21564495017.508.10111002.10EPA 3958168 →
EA*5X25M17A*+ furnace: *96VTN0601716B*AHRI reference: 21564505617.508.10112002.08EPA 3958245 →
EA*5X25M17A*+ furnace: OMV098J12*AHRI reference: 21564512817.508.10111002.10EPA 3958284 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →