N5H5S24*K*AAA*
PERFORMANCE 16 SEER2 HP · source records, page 7
187 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H5S24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 187 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.5 | 187 / 187 |
| EER2 · BTU/Wh | 11.7–13 | 187 / 187 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 187 / 187 |
| Cooling capacity · BTU/h | 22,200–24,400 | 187 / 187 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 21,600–24,000 | 187 / 187 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,200–15,200 | 187 / 187 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,800–11,900 | 187 / 187 |
| COP at 5°F / −15°C | 1.96–2.26 | 187 / 187 |
| Equipment / loop type | HP - Split System | 187 / 187 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 187 / 187 |
| Compressor staging | Single stage | 187 / 187 |
| Connected capability | No | 187 / 187 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X32M17A*+ furnace: *80VSL0701716B*AHRI reference: 214212628 | 15.50 | 7.80 | 11300 | 1.98 | EPA 3411896 → |
FEVB0036**+NAVA53601CKAHRI reference: 214277564 | 15.50 | 7.80 | 11400 | 2.08 | EPA 3415806 → |
FMA5X24**AL*AHRI reference: 214424049 | 15.50 | 7.80 | 10800 | 2.00 | EPA 3425332 → |
FM(C,U)5Z24**AL*AHRI reference: 215828909 | 15.50 | 8.00 | 11300 | 2.10 | EPA 3713322 → |
F5MA5*36L*B*AHRI reference: 216463796 | 15.50 | 7.80 | 11400 | 2.10 | EPA 3847036 → |
FEVA0036**+NAVA53601CKAHRI reference: 217051525 | 15.50 | 8.00 | 11300 | 2.04 | EPA 4027343 → |
FM(C,U)5S36**AL*AHRI reference: 218452318 | 15.50 | 8.00 | 11200 | 2.10 | EPA 4624427 → |
FM(C,U)5S30**AL*AHRI reference: 218452286 | 15.50 | 8.00 | 11200 | 2.10 | EPA 4624459 → |
EA*5X25M17A*+ furnace: *96VSN0601412B*AHRI reference: 214130938 | 15.20 | 7.80 | 11500 | 2.08 | EPA 3399850 → |
EA*5X25M17A*+ furnace: *96MSN0261410A*AHRI reference: 214130858 | 15.20 | 7.80 | 11600 | 2.08 | EPA 3399924 → |
EA*5X25M17A*+ furnace: *96MSN0601412A*AHRI reference: 214130886 | 15.20 | 7.80 | 11600 | 2.08 | EPA 3399981 → |
EA*5X37M17A*+ furnace: *96MSN0261410A*AHRI reference: 214132909 | 15.20 | 7.80 | 11500 | 2.06 | EPA 3400034 → |
EA*5X37M17A*+ furnace: *96MSN0601412A*AHRI reference: 214132937 | 15.20 | 7.80 | 11600 | 2.06 | EPA 3400062 → |
EA*5X37M17A*+ furnace: *96VTN0601412B*AHRI reference: 214133114 | 15.20 | 7.80 | 11500 | 2.06 | EPA 3400100 → |
EA*5X37M21A*+ furnace: *80CTL0451712B*AHRI reference: 214133139 | 15.20 | 7.80 | 11700 | 2.12 | EPA 3400152 → |
EA*5X37M21A*+ furnace: *95MSU0401712A*AHRI reference: 214133229 | 15.20 | 7.80 | 11800 | 2.10 | EPA 3400202 → |
EA*5X37M17A*+ furnace: *80MS(N,L)0451714A*AHRI reference: 214132635 | 15.20 | 7.80 | 11400 | 2.08 | EPA 3400239 → |
EA*5X37M17A*+ furnace: *80CTL0451712B*AHRI reference: 214132687 | 15.20 | 7.80 | 11400 | 2.06 | EPA 3400263 → |
EA*5X25M17A*+ furnace: *96VTN0601412B*AHRI reference: 214131031 | 15.20 | 7.80 | 11500 | 2.08 | EPA 3400290 → |
FHMA5*30L*B*AHRI reference: 214179744 | 15.20 | 7.80 | 11100 | 2.06 | EPA 3404533 → |