H5H8T48*K*AAA*
Mainline 18 SEER2 HP · source records, page 8
415 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for H5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 415 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 415 / 415 |
| EER2 · BTU/Wh | 11.7–13.5 | 415 / 415 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 415 / 415 |
| Cooling capacity · BTU/h | 45,500–50,500 | 415 / 415 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 48,500–52,500 | 415 / 415 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,400–32,400 | 415 / 415 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,200–26,600 | 415 / 415 |
| COP at 5°F / −15°C | 2.1–2.34 | 415 / 415 |
| Equipment / loop type | HP - Split System | 415 / 415 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 415 / 415 |
| Compressor staging | Two-stage | 415 / 415 |
| Connected capability | No | 415 / 415 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X48M21A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 216349544 | 17.00 | 8.00 | 23400 | 2.16 | EPA 3806577 → |
EVD5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 216350288 | 17.00 | 8.10 | 24000 | 2.16 | EPA 3806642 → |
EVD5X48M21A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 216350328 | 17.00 | 8.00 | 23400 | 2.16 | EPA 3806961 → |
EVD5X61M21A*+ furnace: *80VTL0902120B*AHRI reference: 216351072 | 17.00 | 8.50 | 24800 | 2.26 | EPA 3806994 → |
EVD5X48M21A*+ furnace: *96VTN1002122B*AHRI reference: 216350464 | 17.00 | 8.10 | 24000 | 2.18 | EPA 3807030 → |
EVM5X49M21A*+ furnace: *80VSL0902120B*AHRI reference: 216349736 | 17.00 | 8.10 | 25000 | 2.14 | EPA 3807119 → |
EVM5X49M21A*+ furnace: *80VSL1102122B*AHRI reference: 216349744 | 17.00 | 8.10 | 24600 | 2.16 | EPA 3807127 → |
EVM5X49M21A*+ furnace: *80MSU0601716A*AHRI reference: 216349752 | 17.00 | 8.10 | 25000 | 2.14 | EPA 3807134 → |
EVD5X61M21A*+ furnace: *95MSU1002120A*AHRI reference: 216351153 | 17.00 | 8.50 | 24800 | 2.24 | EPA 3807175 → |
EVD5X61M21A*+ furnace: *96VTN0802120B*AHRI reference: 216351185 | 17.00 | 8.10 | 25000 | 2.14 | EPA 3807194 → |
EVM5X60M21A*+ furnace: *95MSU1002122A*AHRI reference: 216350144 | 17.00 | 8.10 | 24400 | 2.18 | EPA 3807436 → |
EVM5X60M21A*+ furnace: *95MSU1002120A*AHRI reference: 216350136 | 17.00 | 8.10 | 24800 | 2.14 | EPA 3807476 → |
EVD5X60M21A*+ furnace: *95MSU1002120A*AHRI reference: 216350888 | 17.00 | 8.10 | 24800 | 2.14 | EPA 3807545 → |
EVM5X60M21A*+WALLCON+ furnace: *80CTL0702120B*AHRI reference: 216350032 | 17.00 | 8.00 | 23800 | 2.16 | EPA 4000331 → |
EVM5X60M21A*+WALLCON+ furnace: *95CSU0802120B*AHRI reference: 216350072 | 17.00 | 8.00 | 23800 | 2.16 | EPA 4000361 → |
EVD5X49M24A*+WALLCON+ furnace: *95CSU0802120B*AHRI reference: 216350600 | 17.00 | 8.00 | 23600 | 2.16 | EPA 4000373 → |
EVM5X49M21A*+WALLCON+ furnace: *95CSU0802120B*AHRI reference: 216349808 | 17.00 | 8.00 | 23800 | 2.16 | EPA 4000418 → |
EVM5X60M21A*+WALLCON+ furnace: *97CMN0802120B*AHRI reference: 216350096 | 17.00 | 8.00 | 23800 | 2.18 | EPA 4000435 → |
EVD5X49M24A*+WALLCON+ furnace: *96CTN0802120B*AHRI reference: 216350656 | 17.00 | 8.00 | 23600 | 2.16 | EPA 4000540 → |
EVD5X49M24A*+WALLCON+ furnace: *97CTN0802120A*AHRI reference: 216350696 | 17.00 | 8.00 | 23600 | 2.16 | EPA 4000572 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.