H5H8T48*K*AAA*
Mainline 18 SEER2 HP · source records, page 2
415 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for H5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 415 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 415 / 415 |
| EER2 · BTU/Wh | 11.7–13.5 | 415 / 415 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 415 / 415 |
| Cooling capacity · BTU/h | 45,500–50,500 | 415 / 415 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 48,500–52,500 | 415 / 415 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,400–32,400 | 415 / 415 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,200–26,600 | 415 / 415 |
| COP at 5°F / −15°C | 2.1–2.34 | 415 / 415 |
| Equipment / loop type | HP - Split System | 415 / 415 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 415 / 415 |
| Compressor staging | Two-stage | 415 / 415 |
| Connected capability | No | 415 / 415 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X49M24A*+ furnace: *80MSU0802120A*AHRI reference: 216350568 | 17.50 | 8.10 | 24600 | 2.16 | EPA 3803530 → |
EVD5X61M21A*+WALLCON+ furnace: *80CSU1002120B*AHRI reference: 216351217 | 17.50 | 8.00 | 23600 | 2.18 | EPA 3803566 → |
EVD5X61M21A*+WALLCON+ furnace: *97CTN0802120A*AHRI reference: 216351225 | 17.50 | 8.00 | 23800 | 2.18 | EPA 3803574 → |
EVD5X61M21A*+WALLCON+ furnace: *97CTN1002122A*AHRI reference: 216351233 | 17.50 | 8.00 | 23600 | 2.18 | EPA 3803582 → |
EVD5X61M21A*+ furnace: *97VTN1002122A*AHRI reference: 216351257 | 17.50 | 8.50 | 24600 | 2.28 | EPA 3803613 → |
EVD5X49M24A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 216350576 | 17.50 | 8.00 | 23400 | 2.20 | EPA 3803865 → |
EVD5X49M24A*+WALLCON+ furnace: *96CTN1202422B*AHRI reference: 216350664 | 17.50 | 8.00 | 23400 | 2.18 | EPA 3803898 → |
EVD5X61M24A*+ furnace: *95MSU1002122A*AHRI reference: 216351401 | 17.50 | 8.50 | 25000 | 2.26 | EPA 3803950 → |
EVD5X61M24A*+WALLCON+ furnace: *96CTN0802120B*AHRI reference: 216351409 | 17.50 | 8.00 | 23600 | 2.18 | EPA 3803958 → |
EVD5X61M24A*+ furnace: *80VSL1102122B*AHRI reference: 216351273 | 17.50 | 8.50 | 25000 | 2.24 | EPA 3804007 → |
EVD5X61M24A*+WALLCON+ furnace: *80CTL0702120B*AHRI reference: 216351289 | 17.50 | 8.00 | 23800 | 2.18 | EPA 3804088 → |
EVD5X61M24A*+WALLCON+ furnace: *97CMN1202422B*AHRI reference: 216351353 | 17.50 | 8.00 | 23600 | 2.18 | EPA 3804113 → |
EVM5X49M21A*+WALLCON+ furnace: *96CTN1002122B*AHRI reference: 216349896 | 17.50 | 8.00 | 23600 | 2.16 | EPA 3804167 → |
EVM5X49M21A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 216349928 | 17.50 | 8.00 | 23400 | 2.20 | EPA 3804202 → |
EVD5X49M24A*+WALLCON+ furnace: *97CTN1202422A*AHRI reference: 216350704 | 17.50 | 8.00 | 23400 | 2.18 | EPA 3805249 → |
EVM5X49M21A*+WALLCON+ furnace: *80CSU1002120B*AHRI reference: 216349936 | 17.50 | 8.00 | 23600 | 2.16 | EPA 3805255 → |
EVM5X49M21A*+WALLCON+ furnace: *97CTN1002122A*AHRI reference: 216349952 | 17.50 | 8.00 | 23600 | 2.16 | EPA 3805271 → |
EVM5X60M21A*+WALLCON+ furnace: *80CSU1002120A*AHRI reference: 216349984 | 17.50 | 8.00 | 25200 | 2.10 | EPA 3805402 → |
EVM5X60M21A*+ furnace: *80MSU0802120A*AHRI reference: 216350016 | 17.50 | 8.10 | 24400 | 2.16 | EPA 3805435 → |
EVD5X60M21A*+ furnace: *80MSU0802120A*AHRI reference: 216350768 | 17.50 | 8.00 | 24400 | 2.16 | EPA 3805478 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.